® PERMAQ Pro 2000 total desal- salts and minerals ination plant. Your BWT PERMAQ® Pro 2000 that have been This installation and operating plant is constructed in a com- removed from the manual contains...
(option) overflows. * SDI: 3.0 %/min the RO plants are WxDxH: Water quality (contact BWT for technical advice) Content Symptom Preventive action Can in some cases be micro-filtrated TOC, BOC and Can cause slimy as well as firm hard film.
¾" flexible pressure pletely (see encl. 13.7 Pos. hoses. stock complete ELECTRICAL assembly kits for the BWT Now switch on the plant CONNECTIONS PERMAQ ® Pro 2000 series. power supply. The plant will The best operating result is ob- now be operating.
Permeate capacity Outlet amount E.g. if the feed water tempera- Permeateca pacity ture is 8 °C, for an BWT ® PERMAQ Pro 2030 it means Ex.: BWT PERMAQ ® Pro 2020 that the permeate capacity will ® BWT PERMAQ...
Maintenance intervals preserved at a standstill lasting compiled by updating BWT 3 days or longer, and by ® PERMAQ Pro’s operating ground water the membranes journal “13.5 Operating jour- must be preserved at a standstill nal”.
9.2.6 Alarm: Level high 9.2.7 The plant is not operating 9.2.8 Alarm: The transport pump stops and starts Check AQUA Flex’s manual chapter 6. Troubleshooting 9.2.9 Hard water is measured at the soft-water tap Check softening plants manual for troubleshooting...
LED’s flash slowly (½ Hz) LED’s flash rapidly (5 Hz) ® BWT PERMAQ Pro emits beep tone at Alarm condition (Nothing is working), which can only be neutralised by rectifying the fault, then switching the plant OFF for 5 seconds and switching ON again.
(desalinated water) is pipe from your usual supplier or Check that the water quality is then led to consumption and can from BWT. <20 µS/cm. This e.g. be collected in a reservoir. The membrane can now be...
NO, the problem does not concerns the plant or the installation The plant - we mean only the part of the whole installation which was delivered by BWT (i.e only the plant). The installation - we mean the piping etc. leading to the plant.
13.5 Operating Journal Maintenance intervals should be performed as described below in the Operating Journal. Replacement frequency ® of wearing parts shown in section 13.6 Spare Parts List BWT PERMAQ Pro 2010-2080.
For BWT PERMAQ Pro 2010-2080 reverse osmosis unit you can select between following options, contact **BWT Sales for further information. 13.8.1 Option 1 - Hose Connector Kit BWT carry complete assembly kits (hose kits) for BWT Part No.: 656530195 ® PERMAQ Pro 2000 reverse osmosis unit.
Option 9 - Mixed-bed If a water quality < 0,5 µS/cm is required, we recom- Part No.: ** mend a BWT HOH Demi Mix (a mixed-bed unit) for post-treatment of the reverse osmosis water. 13.8.10 Option 10 - Upgrade Kit...
13.8.12 Option 12 – Preparation for CIP Part No.: 451202016 for Pro 2010-2040 Preparation for CIP consists of connections which ena- ble installation of a CIP unit on the RO plant Part No.: 451202007 for Pro 2060-2080 13.8.13 Option 13 – Stationary CIP During normal operation, depending on inlet, water quality, temperature, operating conditions etc, the RO membranes will successively loose capacity due to the...
Every third month the reservoir mus tbe rinsed and cleaned before filling in new antiscalant. Above-mentioned dosing amounts are calculated on basis of our standard dimensioning conditions; if you are in doubt, BWT will be pleased to calculate the correct amounts for your plant. 13.8.16 Option 16 –...