Honeywell AirScan iR Instruction Manual page 8

Refrigerant sensor for industrial applications

Advertisement

3
Operation
Pushbutton Operation, LED
B
Indicators, Adjustment Pots and
Test Points
TM
The Manning AirScan
buttons, and two adjustment pots that are utilized for
navigation of test functions, calibrations, and operating
modes. In addition, a pair of test points is also
provided that assist in the connection to standard
meter leads for use in the upcoming calibration and
diagnostic procedures (see Figure 4).
Figure 4. Board Component Layout
ICSP Programming Port
Zero Adjust
Span Adjust
JP3
Note 1: Checking
ZERO
voltage to sensor
at +24 and GND
SPAN
S2
24
VDC
Black
Red
-
+
SIG
+24
GND
SHLD
JP1
Note 2: Reading
signal at TEST+
TEST +
and TEST-
TEST -
40-200
mVDC
Black
Red
-
+
Manning AirScan-iR Refrigerant Sensor
continued
iR has two internal push-
Serial Port
Pushbutton S1
Rx LED
Tx LED
Pushbutton S2
JP2
S1
Draw
Chamber
CALIBRATE
mA FAULT
IR SOURCE
Tubing to
calibration point
19100 AirScan-iR-ind 05/2006 REVA Copyright © 2006 Manning Systems, Inc. All Rights Reserved.
"Zero" adjustment pot — adjusts output
calibration of the 4 mA nominal resting point.
"Span" adjustment pot — adjusts the 20 mA
concentration level or unit span/sensitivity.
Pushbutton S1 — used to initiate the auto-zero
function, program the 4 mA output calibration,
and initiate the 4/20 mA loop test.
Pushbutton S2 — used to program the span
setting.
Test(+) and Test(—) for connection to a DC Volt
meter (see Figure 4, Note 2).
IMPORTANT: The pushbutton(s) must be pressed
the correct number of times and at the correct rate.
When a multi-press sequence must be
performed, the button must be pressed rapidly
and evenly, lifting one's finger completely from
the actuator for each consecutive press.
For press and hold activations, one's finger
must always be applying a down pressure
without disruption for the specified time in order
to activate the desired mode.
See complete details of each operation in other
parts of the manual.
POWER
The AirScan
SYSTEM
5) that blink in specific sequences (see Figure 6 on
FAULT
next page) to indicate sensor operation and
programming modes. A summary of sensor operation
ATMOS
ACTIVE
and programming modes with corresponding LED
blink sequences is shown in Figure 7 on page 10.
Figure 5. LED Layout
Draw
Chamber
TM
iR also has a group of LED's (see Figure
POWER
SYSTEM
CALIBRATE
FAULT
mA FAULT
IR SOURCE
ATMOS
ACTIVE
8