Electrical Schematic And Circuit Connection; Electrical Schematic; Circuit Connection; Outdoor Installation - EAS Electric E300WHF User Manual

Air source heat pump water heater
Table of Contents

Advertisement

Available languages

Available languages

4.4.1 Electrical schematic

4.4.2 Electrical schematic
*Dedicated power supply shall be used for water heater. The supply voltage shall comply with the rated voltage
required in the nameplate;
*The power supply circuit of the water heater must be reliably grounded;
*Wiring construction must be carried out by professional installation technical personnel according to wiring
diagram;
*Electric leakage protector shall be properly set according to the requirements of technical standards of relevant
electrical equipment of the state;
After all wiring tasks are completed and no mistake is found after careful inspection, the power supply can be
connected.

4.5 Outdoor installation

4.5.1 Indoor installation is recommended;
4.5.2 A shed is needed on the top of unit when the machine installs in the outdoor. The picture as below: