C7355B In-Duct IAQ Monitor
COMMERCIAL GRADE IAQ PRODUCTS
E
Keep these instructions
together with the device or
with the equipment
documentation! Only qualified
personnel may perform
electrical connections for
230 VAC.
D
Diese Anleitung ist beim Gerät
oder in der
Anlagendokumentation
aufzubewahren! Elektrisches
Anschließen von 230 VAC ist
nur durch autorisiertes
Fachpersonal gestattet.
DK
Opbevar denne vejledning
sammen med regler eller med
anlægsdokumentationen!
Elektrisk tilslutning for
230 VAC bør kun foretages af
autoriserede personer.
ES
Conserve estas instrucciones
con el recalar o con la
documentación de la
instalación. La conexión
eléctrica a 230 VCA debe
hacerse solamente por
personal qualificado
SC
请将此装配说明书与设备或者与设备
的其他文档保存在一起! 230 V 交
流电的接线 操作仅允许由合格的专
业人员执行
F
Cette instruction est à conserver
avec le contrôleur ou avec la
documentation de l'installation!
Le raccordement électrique
pour le 230 VAC ne peut être
effectué que par le personnel
autorisé.
I
Queste istruzioni devono essere
conservate insieme al lettore o
con la documentazion e
dell'imianto! I collegamenti a
230 VAC devono essere eseguiti
da personale qualificato.
N
Denne veiledningen skal
oppbevares sammen med regler
eller anleggsdokumentasjonen!
Elektrisk tilkopling med
230 VAC må kun utføres
av fagfolk.
NL
Deze handleiding moet bij de
regelaar, of met de
documentatie van de installatie
worden bewaard! De elektrische
aansluiting voor 230 VAC mag
alleen door geautoriseerd
personeel worden uitgevoerd.
TC
請將此裝配說明書與設備或者與設備的
其他文件儲存在一起!
僅能由合格的專業人員進行230 V交流
電 的接線作業。
MOUNTING INSTRUCTIONS
P
Guarde estas instruções junto
do regulador ou junto da
documentação da instalação! A
ligação eléctrica a 230 VAC só
deve ser efectuada por pessoal
especializado.
S
Denna instruktion skall
förvaras tillsammans med
regler eller
anläggningsdokumentationen!
Elektrisk anslutning med
230 VAC får endast utföras av
behörig personal.
FI
Tätä ohjetta tulee säilyttää
laitteen läheisyydessä tai
yhdessä muiden dokumenttien
kanssa! Vain asianmukaiset
oikeudet omaava henkilö saa
suorittaa 230 VAC
käyttöjännitteen liitäntätöitä.
PL
Instrukcję obsługi należy
przechowywać przy urządzeniu
albo w dokumentacji
technicznej. Tylko
autoryzowany servis jest
upoważniony do podłączenia
do 230 VAT.
K
본 설치 설명서를 해당 장치 또는 관련
문서 와 함께 보관하시기 바랍니다 .
230VAC 전원 연결은 관련 작업 전문가
에 의 해 수행되어야 합니다 .
31-00440-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell C7355B

  • Page 1 C7355B In-Duct IAQ Monitor COMMERCIAL GRADE IAQ PRODUCTS MOUNTING INSTRUCTIONS Keep these instructions Cette instruction est à conserver Guarde estas instruções junto together with the device or avec le contrôleur ou avec la do regulador ou junto da with the equipment documentation de l'installation! documentação da instalação! A...
  • Page 2: When Installing This Product

    C7355B IN-DUCT IAQ MONITOR SUPPORTED DOCUMENTS • IAQ Monitor Submittal Data, 31-00439 — The device should be installed in an accessible • IAQ Monitor User Guide, 31-00438 location that is convenient for regular mainte- • IAQ Monitor Quick Start Guide, 31-00441 nance.
  • Page 3: Monitor Overview

    C7355B IN-DUCT IAQ MONITOR Monitor Overview INSTALLATION The image below illustrates the typical enclosure of the Assembly of main unit and Pitot Tube IAQ monitor. There is a pitot tube, main unit sensor compartment and main unit communication control 1. See markings on the main unit, as shown in Fig. 2.
  • Page 4 C7355B IN-DUCT IAQ MONITOR 3. As shown in Fig. 4, install the side of the pitot tube FOR AIR FLOW FROM RIGHT TO LEFT (RIGHT IS THE marked with the Windward Side facing down, and FACTORY DEFAULT) align it with the rear mounting hole of the main unit.
  • Page 5 C7355B IN-DUCT IAQ MONITOR 4. Rotate it 90 degrees clockwise to fix to complete 2. Pull out the air inlet filter (left side of Fig. 11) from installation (see Fig. 9). the lower right side of the sensor module, and then remove the fixing screws on the middle of the mod- ule (right side of Fig.
  • Page 6 C7355B IN-DUCT IAQ MONITOR NOTE: When the sensor module is installed to the origi- 5. Put the sensor compartment cover back in place and nal position, the cable should be passed under attach it with the original screws. the compartment shown in Fig. 13. Do not pass over the compartment, otherwise the sensor module cannot be fixed normally.
  • Page 7: Wiring Diagram

    C7355B IN-DUCT IAQ MONITOR 8. Install the main unit. Connect the main unit horizon- Wiring Diagram tally with the pitot tube interface (as shown in Fig. 18) Fig. 18. 9. Then rotate it 90 degrees clockwise (Fig. 19). The installation is completed.
  • Page 8 C7355B IN-DUCT IAQ MONITOR 2. Remove the two terminal blocks for power supply 4. Connect the cables to the terminal blocks. and RS-485 respectively. Fig. 24. 5. Plug the terminal blocks back onto the pin connec- Fig. 22. tors and tighten the waterproof connectors.
  • Page 9 C7355B IN-DUCT IAQ MONITOR 6. Replace the cover of the electrical wiring compart- ment and tighten the screws. Fig. 26. 31-00440—01...
  • Page 10: Dimensions And Mounting Holes

    C7355B IN-DUCT IAQ MONITOR DIMENSIONS AND MOUNTING HOLES Fig. 27. Dimensions in in. (mm). 31-00440—01...
  • Page 11 C7355B IN-DUCT IAQ MONITOR 31-00440—01...
  • Page 12 C7355B IN-DUCT IAQ MONITOR Honeywell Building Technologies Honeywell 715 Peachtree Street NE Atlanta, GA 30308 customer.honeywell.com Honeywell Building Technologies Honeywell GmbH Böblinger Strasse 17 ® U.S. Registered Trademark 71101 Schönaich, Germany ©2020 Honeywell International Inc. 31-00440—01 M.S. 11-20 buildings.honeywell.com Printed in United States...

Table of Contents