Loading the cabinet:

Each shelf will accommodate 2 cylinders stored horizontally.
Inspections & Maintenance:
If a problem is discovered during an inspection, restore the cabinet to normal operating
condition BEFORE using it again. DO NOT use the cabinet to store LPG cylinders if the cylinder supports or
cabinet feet are structurally damaged. If damaged, the cabinet might fall over and any stored cylinder could be
damaged. If you notice structural damage, immediately remove all cylinders, tag the cabinet "Out of Service", and
report the problem to maintenance personnel.
The cylinder cabinet requires minimal maintenance:
1) Apply grease to any hinge that squeaks or operates roughly;
2) Inspect the cabinet at least once per month. Check for corrosion and/or rust that might occur in places where
the paint is damaged or missing:
i)
Remove rust with a steel bristle brush (or sandpaper); then apply touchup paint or clear finish to the
affected area;
ii) Inspect the feet of the cabinet to verify structural soundness:
 Remove rust and reseal if necessary;
 Check for deformation, for example bending, warping, or cracking;
iii) Inspect the cylinder supports:
 Remove rust and reseal if necessary;
 Check for deformation (bending, warping, or cracking).

Label placement diagram:

The cabinet should be labeled as shown below. Contact Vestil to order replacement labels.
Label 287: Model & capacity
Label 204: Secure frame to floor
Rev. 5/16/2014
Copyright 2014 Vestil Manufacturing Co.
Page 7 of 8
CYL-H-4-KD, manual.doc
Label 735: FLAMMABLE – NO SMOKING
Label 203: