Turbo E4T Use And Maintenance Instructions

Turbo E4T Use And Maintenance Instructions

Rcp enclosure with integrated sequencer

Advertisement

Quick Links

U s e r I n s t r u c t i o n s
R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r
R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r
Description ____________________________________________________________________ 2
Functioning ____________________________________________________________________ 2
Features _______________________________________________________________________ 2
Dimensions ____________________________________________________________________ 3
Installation _____________________________________________________________________ 3
Warnings _______________________________________________________________________ 3
Maintenance ___________________________________________________________________ 4
Electric Connections ___________________________________________________________ 4
Control Board Connection Layout ______________________________________________ 5
Connecting Power Adapter Board Vac __________________________________________ 6
Adjustment of Cycles and Times ________________________________________________ 7
Disassembly Of The Pilot Enclosures ___________________________________________ 9
I n M n 2 8 C R C S I
e n
R e v . 0 0
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y
Use And Maintenance Instructions
T U R B O s . r . l .
D u s t F i l t e r C o m p o n e n t s
T e l + + 3 9 0 3 6 2 5 7 4 0 2 4
F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E4T and is the answer not in the manual?

Questions and answers

Summary of Contents for Turbo E4T

  • Page 1: Table Of Contents

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Use And Maintenance Instructions Description ____________________________________________________________________ 2...
  • Page 2: Description

    The pilot enclosure allows remote control valve activation; the series of ESRM pilots is managed by the E4T sequencer. The electric signals coming from the E4T sequencer command the coils activating the pneumatic pilot.
  • Page 3: Dimensions

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Dimensions Installation De-pressure the piping before installation.
  • Page 4: Maintenance

    The tools must be examined during use to prevent excessive wear. If a problem should occur during installation or maintenance, or if in doubt, contact Turbo Srl or its Authorised Representative. Electric Connections The electric connections must only be performed by qualified staff and must be compliant with the regulations in force in the country of installation.
  • Page 5: Control Board Connection Layout

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Control Board Connection Layout Connector J3 Position...
  • Page 6: Connecting Power Adapter Board Vac

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Connecting Power Adapter Board Vac Position Description...
  • Page 7: Adjustment Of Cycles And Times

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Adjustment of Cycles and Times To set the cycles of the sequencer, the three rotary switches SW1 - SW2 - SW3 must be adjusted;...
  • Page 8 R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r The E4T sequencer board functions at 24 Vdc. The accessory power supply board with transformer is mounted In the RCP enclosures at 115 and 230 Vac.
  • Page 9: Disassembly Of The Pilot Enclosures

    U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Disassembly Of The Pilot Enclosures Sequence Remove the M8 slotted hex head 13 mm screws.
  • Page 10 U s e r I n s t r u c t i o n s R C P E n c l o s u r e W i t h I n t e g r a t e d E 4 T S e q u e n c e r Note Lubricate the O-rings with top quality silicone grease.
  • Page 11 Declaration Of Conformity Of The Manufacturer The Manufacturer: TURBO SRL The Manufacturer's Address: Via Po 33/35 20811 Cesano Maderno (MB), Italy Declares That Product Name: RCP Enclosure With Sequencer E4T Models: Complies with the following directives: Electromagnetic Compatibility Directive 2014/30/EU,...

Table of Contents