TURBO s.r.l. Electronic Control Systems For Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.eu TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 SEQUENCER 24 Vac 20 ÷ 24 OUTPUTS User Manual 05/01/2016 Manual Release 1.00 Hardware Release 1.01...
Page 2
General Description Sequencer for controlling the pneumatic cleaning function of industrial dust collection systems. The device has three output relays contacts and two digital input contacts. A large, bright display is provided for reading the filter obstruction level, the active solenoid valves and any alarms in any moment. Technical Specifications Casing Made of insulating, ABS base and polycarbonate lid.
Page 3
Electric Specifications W a r n i n g ! R e a d t h e s e c t i o n o n i n s t a l l a t i o n b e f o r e c o n n e c t i n g Electric Power t h e d e v i c e .
Page 4
Warning Symbols Used In This Manual The information regarding safety are highlighted using the symbols: Warning-Danger Generic - Warning- Risk – Danger Electric Current Dispose according to the standards for electrical and electronic equipment RAAE Installation Rules Notes and Warnings Protect the device from direct exposure to sunlight.
Page 5
The cable glands must be chosen according to the diameter of the cable to be used. The sealing of the press cable is guaranteed by the compression of the rubber gasket that tightens on the outer diameter of the cable. The tightness of the cable gland is guaranteed by the compression of the rubber seal that tightens on the outer diameter of the cable.
Page 6
Display / Keypad There are four round buttons on the front panel for controlling the device and turning on the display as shown in the following figure. The SET button enables to enter and exit the programming menu, and activate the manual solenoid test by selecting function F06.
Page 7
List of Functions F02: Solenoid activation time. Possible values: 0.05” – 5.00” step 0.01”. Default = 0.20”. F03: Washing pause time between solenoid valves. Possible values: 001” – 999” step 1”. Default = 020”. F04: Number of connected outputs. Possible values: 01 – 24 step 1. Default = 001.
Page 8
Alarms The unit runs a number of checks during the start-up cycle and during normal operation. The possible alarms and respective solutions are shown in the following table. A. No. Description Action - For 24Vdc, switch the device off and move the AC/DC jumpers to DC. F05 set to 24Vdc –...
Page 9
Indicates that a valve in short circuit has been excluded from the cycle. The signaling of the code E14 alternates with the indication of the interested output, is shown as Uxx Turn off the device and then turn it where xx is the number of the back on, after having verified the output.
Page 10
Description Of Operation The installed SW version and the symbol ---, meaning that coherence between settings stored in E2Prom and the set jumpers is being checked, will appear on the display when the sequencer is powered up. A corresponding error code will appear in case of discrepancies between settings (see Alarms Table).
Page 12
Contacts And Relay Terminal Block J4 Enable contact input consensus 14.15 terminals. Is used to activate the control unit remotely, it can be turned on and off remotely. The unit is supplied with a jumper on the two terminals 14:15, without it will not turn on.
Page 13
Terminal Table To access at the terminal blocks of the control board, unscrewing countersunk screws of the cover panel blue. Main Board Terminal Description Terminal Description Power Supply 24 Vac Solenoid output 16 Power Supply 24 Vac Solenoid output 17 Earth (GND) Solenoid output 18 Solenoid output 19...
Page 16
Maintenance Only the fuses, batteries and SD card can be replaced. All other repairs must be done by the manufacturer. Default Settings Function Description Set Value Number Solenoid valve activation time 0.20 Sec. Washing pause time between solenoid valves in normal 020 Sec.
Page 17
Disposal Do not disperse in the environment after use. Dispose of the product according to current regulations for the disposal of electronic equipment. This device is used in a dust collector system and, therefore, it is part of a fixed installation.
Page 18
Problem Solution Fault Possible Cause Solution The display does not light Burnt fuse. Check the protection fuse on the power voltage. Check that the power voltage is present and compliant with that required for the device (terminals 01 and 03). The outputs are not Incorrect output voltage.
Page 19
TURBO SRL The Manufacturer's Address: Via Po 33/35 20811 Cesano Maderno (MB), Italy Declares that: Product Name: Sequencer E1T Product Options: Complies with the following directives: Directive 2014/30/EU Electromagnetic Compatibility compliant with Harmonised European standards EN61000-6-2:2005 class B of EN61000-6-4:2001...