General Description Sequencer for controlling the pneumatic cleaning function of industrial dust collection systems. The device has three output relays contacts and two digital input contacts. A large, bright display is provided for reading the filter obstruction level, the active solenoid valves and any alarms in any moment. Technical Specifications Casing Made of insulating, ABS base and polycarbonate lid.
Page 3
Electric Specifications W a r n i n g ! R e a d t h e s e c t i o n o n Electric Power i n s t a l l a t i o n b e f o r e c o n n e c t i n g t h e d e v i c e .
Page 4
Installation Instructions / Notes and Warnings Protect the device from direct exposure to sunlight. Do not position the device near or directly in contact with sources of heat or electromagnetic fields. Connect the device to power lines other than those for operating motors or other large power devices which could generate network interference.
Page 5
Display Keypad There are four round buttons on the front panel for controlling the device and turning on the display as shown in the following figure. The SET button enables to enter and exit the programming menu, and activate the manual solenoid test by selecting function F06.
Page 6
List of Functions F02: Solenoid activation time. Possible values: 0.05” – 5.00” step 0.01”. Default = 0.20”. F03: Washing pause time between solenoid valves. Possible values: 001” – 999” step 1”. Default = 20”. F04: Number of connected outputs. Possible values: 01 - 99 Depending on the version of the instrument, step 1.
Page 7
Alarms The unit runs a number of checks during the start-up cycle and during normal operation. The possible alarms and respective solutions are shown in the following table. A. No. Description Action - For 24Vdc, switch the device off and move the AC/DC jumpers to DC.
Page 8
Output short circuit The signaling of the code E08 Turn off the device and then turn it back alternates with the indication of the on, after having verified the plant of the interested output is shown as Uxx solenoid valves. where xx is the number of the output.
Page 9
Description Of Operation The installed SW version and the symbol ---, meaning that coherence between settings stored in E2Prom and the set jumpers is being checked, will appear on the display when the sequencer is powered up. A corresponding error code will appear in case of discrepancies between settings (see Alarms Table).
Page 11
Contacts And Relay Terminal Block J4 Enable contact input consensus 14.15 terminals. Is used to activate the control unit remotely, it can be turned on and off remotely. The unit is supplied with a jumper on the two terminals 14:15, without it will not turn on.
Page 12
Connection Diagram Expansions Expansion Up To 32 Channels Expansion Up To 40 Channels...
Page 18
Terminal Table To access at the terminal blocks of the control board, unscrewing countersunk screws of the cover panel blue. Main Board Terminal Description Terminal Description Power Supply 115 230 Vac Solenoid output 15 Power Supply 115 230 Vac Solenoid output 16 Earth (GND) Solenoid output 17 Solenoid output 18...
Page 19
Expansion Boards Expansion up to 32 channels Expansion up to 40 channels Terminal Description Terminal Description Earth (GND) Earth (GND) Solenoid valve common Solenoid valve common Solenoid output 25 Solenoid output 33 Solenoid output 32 Solenoid output 40 Expansion up to 48 channels Expansion up to 56 channels Terminal Description...
Page 20
Expansion up to 80 channels Expansion up to 88 channels Terminal Description Terminal Description Earth (GND) Earth (GND) Solenoid valve common Solenoid valve common Solenoid output 73 Solenoid output 81 Solenoid output 80 Solenoid output 88 Expansion up to 96 channels Expansion up to 99 channels Terminal Description...
Page 22
Installation And Casing Dimensions W e ig ht 4.8 Kg...
Page 23
Maintenance Only the fuses, batteries and SD card can be replaced. All other repairs must be done by the manufacturer. Default Settings Function Description Set Value Number Solenoid valve activation time 0.20” Washing pause time between solenoid valves in normal 020”...
Page 24
Disposal Do not disperse in the environment after use. Dispose of the product according to current regulations for the disposal of electronic equipment. This device is used in a dust collector system and, therefore, it is part of a fixed installation.
Page 25
Problem Solution Fault Possible Cause Solution The display does not light Burnt fuse. Check the protection fuse on the power voltage. Check that the power voltage is present and compliant with that required for the device (terminals 01 and 03). The outputs are not Incorrect output voltage.
Page 26
TURBO SRL The Manufacturer's Address: Via Po 33/35 20811 Cesano Maderno (MB), Italy Declares that: Product Name: Sequencer E1T Product Options: Complies with the following directives: Machinery Directive 2006/42/EC 'Electromagnetic compatibility' compliant with Harmonised European standards EN61000-6-2:2005 class B of EN61000-6-4:2001...