About This Documentation; Additional Documentation; Presentation Of Information; Warnings - Emerson AVENTICS PM1 Operating Instructions Manual

Electromechanical pressure switch
Hide thumbs Also See for AVENTICS PM1:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8

1 About This Documentation

Read this documentation carefully, especially the section "Notes on Safety" , be-
fore working with the product.
These instructions contain important information on the safe and appropriate as-
sembly, operation, and maintenance of the product and how to remedy simple
malfunctions yourself.

1.1 Additional documentation

In addition to this documentation, you will obtain further documents on the
product or the machine/system where it is installed.
Observe all documents supplied with the system or machine.
u
Additionally always observe the following regulations:
• General, statutory and other binding rules of the European and national laws.
• Applicable regulations for accident prevention and environmental protection.

1.2 Presentation of information

1.2.1 Warnings

Warnings of personal injury and damage to property are highlighted in this docu-
mentation. The measures described to avoid these hazards must be followed.
Display as highlighted box
Warnings are displayed in the form of highlighted boxes with the following struc-
ture:
Hazard type and source
Consequences
u Precautions
Presentation with highlighted signal word
Instructions and lists often contain warnings that are integrated into the text.
They are introduced with a bold signal word:
CAUTION! Do not exceed permissible bending radii.
Meaning of the signal words
Signal word
Meaning
Warning
Possible danger to the life and health of persons.
Failure to observe these notices can result in serious health conse-
quences, including death.
Caution
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or dam-
age to property.

1.2.2 Symbols

Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.

2 Notes on Safety

The product has been manufactured according to the accepted rules of current
technology. Even so, there is a risk of injury or damage if the following general
safety instructions and the specific warnings given in this instruction manual are
not observed.
• Please read all these instructions carefully before working with the product.
• Keep these instructions in a location where they are accessible to all users at
all times.
• Always include the operating instructions when you pass the product on to
third parties.

2.1 Intended use

The product may only be commissioned after it has been installed in the ma-
chine/system for which it is intended.
• Only use the pressure switch to open and close electrical contacts using com-
pressed air.
• Only use compressed air or hydraulic oil as the medium.
AVENTICS™ PM1 | R412018457-BAL-001-AI | English
SIGNAL WORD
• Use is permitted only under the operating conditions and within the perfor-
mance limits listed in the technical data.
• The pressure switch is only intended for industrial applications.
Intended use includes having read and understood these instructions completely,
especially the section "Notes on Safety".

2.2 Personnel qualifications

All tasks associated with the product require basic mechanical, pneumatic and
electrical knowledge, as well as knowledge of the respective technical terms. In
order to ensure operational safety, these tasks may only be carried out by quali-
fied personnel or an instructed person under the direction of qualified personnel.
Qualified personnel are those who can recognize possible dangers and institute
the appropriate safety measures, due to their professional training, knowledge,
and experience, as well as their understanding of the relevant regulations per-
taining to the work to be done. Qualified personnel must observe the rules rele-
vant to the subject area.

2.3 General safety instructions

• Observe the valid local regulations to protect the environment in the country
of use and to avoid workplace accidents.
• Only use AVENTICS products that are in perfect working order.
• Examine the product for obvious defects, such as cracks in the housing or
missing screws, caps, or seals.
• Do not modify or convert the product. The warranty will not apply if the prod-
uct is incorrectly assembled.
• Product warnings and information must be legible, i.e. not covered by paint,
etc.

2.3.1 Safety instructions related to the product and technology

• Lay cables and lines so that they cannot be damaged and no one can trip over
them.
• Do not operate the product in aggressive ambient air (e.g., solvent vapors).
• Do not use the product in environments that are not splashwater-proof.
• Operation in an explosive atmosphere is not permissible. There is a danger of
fires and explosions!
• The product may not come into contact with aggressive substances in liquid
or vapor form. These substances include benzene, acetone, nitro vapors, and
liquids containing softeners.
• Only operate the product within the approved operating voltage range.
Only operate M12x1 versions via power packs with protective extra-low volt-
age (PELV) and secure electrical isolation from the operating voltage in accor-
dance with EN 60204, and form A versions in accordance with EN 175301-803
up to 250 V.
• Assembly outdoors is only permitted if there is sufficient protection against
critical ambient conditions such as an aggressive or salty atmosphere, large
fluctuations in temperature, etc.

3 Scope of Delivery

• 1x electromechanical pressure switch, form A or M12x1
• 1x electrical connector, depending on the version (only for form A)
• 2x mounting screw, for flange version (CNOMO without mounting screws)
• 1x O-ring, for flange version (CNOMO without O-ring)
• 1x Operating instructions

4 About This Product

4.1 Product description

The pressure switch is used to open or close an electrical contact when a preset
pressure value is reached.

4.2 Performance specifications

An appropriate medium is applied to the pressure switch at the G1/4 connection
or on the flange. A diaphragm actuates a microswitch (change-over switch) via a
mechanism once the preset switching pressure is reached.
9

Advertisement

Table of Contents
loading

Table of Contents