in compliance with the UNI 10683- EN 1856-1-2-
EN 1857- EN 1443- EN 13384-1-3- EN 12391-1
standards both regarding the dimensions and the
materials used in its construction.
RAMSHACKLE flues, made of unsuitable material
(fibre cement, galvanised steel, etc. with rough,
porous inner surfaces) are illegal and prevent the
stove from working correctly.
The discharge of fumes through a traditional
fireplace (Fig. 5.8) can be done provided that the
chimney is maintained;
If the chimney has a bigger section, it must be
"intubated" with a suitably insulated steel pipe (with
diameter in line with the route) (Fig. 5.9).
Make sure that the connection to the brickwork
chimney is properly sealed.
If the pipes pass through roofs or wooden walls,
you should use special certified transition kits,
commercially available.
.
5.6 LEVELLING THE STOVE
The stove must be levelled, with the help of a spirit
level, by regulating the adjustable feet (if included)
fig. 5.10).
A B = Spirit Level
1
3
1) Vermiculite and/or mineral wool.
2) Steel piping.
3) Closing panel.
Fig. 5.9
Principal Air
Exhaust
02/2021 - EN
A) Windproof cowl
B) Seal
C) Inspect
Smoke
Exhaust
Principal Air