termovana FANCY 12 General Information - Warnings - Installation - Maintenance

termovana FANCY 12 General Information - Warnings - Installation - Maintenance

Air pellet stoves

Advertisement

Quick Links

EN
GENERAL INFORMATION - WARNINGS - INSTALLATION - MAINTENANCE
It is recommended to carefully read the instructions before installation, maintenance or use of the product.
AIR PELLET STOVES
FANCY 12
ECO
CONTO
DESIGN
TERMICO
2022
This manual is an integral part of the product.
Product images are purely indicative.
This product complies with the 4-star class
as per the emission and performance standards
of Italian Legislative Decree no. 186, 7th November 2017

Advertisement

Table of Contents
loading

Summary of Contents for termovana FANCY 12

  • Page 1 GENERAL INFORMATION - WARNINGS - INSTALLATION - MAINTENANCE AIR PELLET STOVES FANCY 12 CONTO DESIGN TERMICO This product complies with the 4-star class 2022 as per the emission and performance standards of Italian Legislative Decree no. 186, 7th November 2017 This manual is an integral part of the product.
  • Page 2 Wi-Fi module allowing the automatic optional Wi-Fi module allowing the automatic management of functions through the management of functions through the Termovana App available on Apple Store and Termovana App available on Apple Store and Google Play. Google Play.
  • Page 3 INDEX GENERAL INTRODUCTION > 4-6 EXAMPLE OF PROGRAMMING SYMBOLS DESTINATION OF USE STOVE PARAMETERS > 20 SCOPE AND CONTENTS OF MANUAL LOADING PELLETS STORAGE OF MANUAL FUME EXTRACTION UPDATE OF THIS MANUAL ROOM FAN GENERAL INFORMATION MAIN STANDARDS APPLIED AND TO BE APPLIED LEGAL WARRANTY LANGUAGE SELECTION MANUFACTURER'S LIABILITY...
  • Page 4: General Introduction

    PURPOSE AND CONTENTS OF THE GENERAL INTRODUCTION MANUAL The product, subject of this manual, was The purpose of the manual is to provide the basic manufactured and tested according to the safety rules and the basis for correct product installation, requirements stated in the reference European maintenance and use.
  • Page 5: Legal Warranty

    1.7 MAIN STANDARDS OBSERVED AND personnel, shall invalidate the warranty. TO BE OBSERVED • Parts subject to normal wear such as gaskets, glass, cast iron cladding and grilles, painted, chrome- A) Directive 2014/35/EU: "Electrical equipment plated or gilded details, handles and electrical designed for use within certain voltage limits'.
  • Page 6: Manufacturer's Liability

    regulations, any guarantee of containment of airborne the manufacturer's data, the serial number and the and noise pollution is also excluded; marking 1.14 STOVE DELIVERY The company declines all liability for any The stove is delivered perfectly packed with damage that may, either directly or indirectly, cardboard or heat-shrinkable sheet and secured to be inflicted upon persons, animals or property a wooden platform that allows it to be moved using...
  • Page 7: Safety Warning

    SAFETY WARNING 2.2 WARNING FOR THE MAINTENANCE TECHNICIAN 2.1 WARNING FOR THE INSTALLER Observe the prescriptions contained in this manual. • Always use individual safety devices and other Observe the prescriptions contained in this manual. means of protection. • The stove removal and installation instructions are •...
  • Page 8 • Before performing any type of operation, wait for • Do not switch off the stove by disconnecting the the flame in the combustion chamber to fully drop mains electrical connection. until it is completely extinguished and cooled, and • Do not lean on the open door, it could compromise always detach the plug from the power socket.
  • Page 9: Storage Of Pellets

    CHARACTERISTICS OF FUEL 3.1 FUEL CHARACTERISTICS The pellet (fig. 3.1) is composed of various types of wood, compressed using mechanical processes in accordance with environmental protection laws and is the only type of fuel intended for this type of stove. The efficiency and thermal potential of the stove may vary depending on the type and quality of the pellets used.
  • Page 10: Installation

    INSTALLATION 5.3 STOVE INSTALLATION SITE On page 34 of this manual, the minimum clearances are shown, expressed in cm, which must be 5.1 GENERAL CONSIDERATIONS respected when positioning the stove with respect In the following paragraphs there are some to combustible materials and objects. guidelines to follow in order to obtain the maximum Protect all structures which could ignite if exposed performance of the product purchased.
  • Page 11: Combustion Air

    5.4 COMBUSTION AIR During use, the stove withdraws a certain quantity of air from the environment where it is located (except for products in the hermetic series, which can withdraw air directly from the outside); this air must be reintegrated through an external air intake (fig. 5.3 - PA = Air Intake).
  • Page 12 Stoves of the "Hermetic" series If a pellet stove in the “Hermetic” series is installed, alternatively it is possible to: fig. 5.4 channel the combustion air using a coaxial exhaust pipe for the expulsion of the flue gases and air withdrawal; therefore it is not necessary to create a classic air intake in the room (fig. 5.5 A,B = Air inlet C,D = Flue gas outlet);...
  • Page 13: Levelling The Stove

    1) Vermiculite and/or mineral wool. A) Windproof cowl 2) Steel piping. B) Seal C) Inspect 3) Closing panel. Fig. 5.9 Fig. 5.8 in compliance with the UNI 10683- EN 1856-1-2- EN 1857- EN 1443- EN 13384-1-3- EN 12391-1 standards both regarding the dimensions and the materials used in its construction.
  • Page 14 5.7 CONNECTION TO SYSTEMS 5.7.1 Electrical connection Just connect the stove to the electrical system using the plug provided. The electrical connection (plug) must be easily accessible even after installing the stove. If the power cord is damaged, it must be replaced by the technical assistance service or by a qualifi ed technician in order to prevent any risk.
  • Page 15: Maintenance

    MAINTENANCE (To be performed by a qualifi ed technical support centre) 6.1 MAINTENANCE Maintenance operations must be performed by an authorised technical assistance centre. Before performing any maintenance operation, take the following precautions: Make sure that all the parts of the stove are cold. Make sure that the ashes are completely extinguished. Use personal protective equipment provided for by Directive 89/391/EEC.
  • Page 16: Demolition And Disposal

    CONTROL AND MAINTENANCE EACH EACH PROGRAMME IGNITION WEEK MONTH YEAR (y) BURN POT ASH DRAWER GLASS ROOM FAN EXTRACTION GRILLE BOILER HEATING ELEMENT SLEEVE EXHAUST MANIFOLD DOOR AND BURN POT GASKETS* FLUE DUCT* FANS* To be performed by a qualified technical support centre. At least once a year or every 4 tonnes of burnt pellets. DEMOLITION AND DISPOSAL The responsibility for the demolition and disposal of the stove is the exclusive responsibility of the owner who must act in compliance with the laws on safety, respect and protection of the environment, in force in the country...
  • Page 17: First Start-Up

    8.1 INTRODUCTION The board automatically controls the various operating parameters of the stove. The user can control the stove manually, to switch it on or switch it off, or use the advanced functions such as the weekly programmer or the timer. 8.2 FIRST START-UP Once the board is powered, the LCD display will show the software version and then the stove status which, in the case of first ignition, will be off.
  • Page 18 8.4 MAIN MENU exceeds the delta T value set in system parameter 64, the stove will enter pellet saving mode and Setting the Temperature start cooling. The stove will restart automatically if the room temperature drops below the set The desired room temperature is set using the temperature for at least 1 minute.
  • Page 19: User Programming

    USER PROGRAMMING 9.9 Program Type Set either an ignition programme, ON, or power off User programming is possible through the menu, programme, OFF. which can be opened by pressing the SET key on 9.10 Enabling the Program the illuminated display panel. To exit the menu at any time without making any changes, press the This function is essential, because if in the disabled STOP key.
  • Page 20: Stove Parameters

    10 STOVE PARAMETERS 13.1 Ducted left In this menu, you can set the left motor ducting or Press SET to open and modify the main stove ventilation speed from 1 to 5, which allows you to parameters such as pellet load, flue gas extraction choose the heat propagation speed. If the value is speed, ambient air fan and ambient temperature set to AUTO, the ventilation follows the set power correction.
  • Page 21: Diagnostic Errors

    14 DIAGNOSTIC ERRORS If during any stage of stove operation there is a mains power failure, when the power returns, a no During operation, if a fault is detected the stove mains power alarm is notified and the stove shuts turns off, following the cooling cycle, and an error down. Even a power failure lasting a few seconds message is shown on the display, which can generates the alarm.
  • Page 22: Preliminary Operations

    15 PRELIMINARY OPERATIONS 15.1 LOADING PELLETS The fi rst operation to perform before switching the stove on is to fi ll the fuel (pellet) tank using the relevant scoop. Be careful not to touch the hot parts if fuel refi lling is carried out with the stove running. Do not empty the bag directly into the tank to avoid loading sawdust or other foreign elements that could compromise correct functioning of the stove and to avoid dispersing the pellets outside...
  • Page 23 To switch it on again, it is advisable to wait for the stove to cool completely. The stove should always be turned off strictly in accordance with the above, and absolutely not by disconnecting it from the mains power. 15.5 OPERATION WITH AMBIENT PROBE ON STOVE The stove can be switched on/off manually or programmed.
  • Page 24 PROBLEM CAUSE SOLUTION Check that the plug is connected to the The stove is without USER mains. power Replace the safety fuses in the electrical The safety fuses in the TECHNICIAN socket (3.15A-250V). electrical socket are blown The control display TECHNICIAN Faulty control display Replace the control display.
  • Page 25 PROBLEM CAUSE SOLUTION Check the following items: any obstructions to the combustion air inlet from the back or Insufficient under the stove; blocked holes in the burn TECHNICIAN combustion air pot grille and/or too much ash in the burn pot housing, Have the extractor blades and impeller cleaned.
  • Page 26 16 CLEANING The cleaning operations can be performed by the user as long as all the instructions given in this manual have been read and understood. It is recommended to carry out the cleaning operations with the stove off and cold. Opening the door To open the door, use the opening lever wearing a glove for high temperatures.
  • Page 27 Fig. 3 Once per year, clean any soot using brushes. The cleaning operation must be carried out by a fl ue specialist, who must clean the duct of any fl ue gases, the fl ue and the chimney stack, also checking their effi ciency and issuing a written declaration confi rming the safety of the system. This operation must be carried out at least once per year.
  • Page 28: Hot Air Ducting

    17 HOT AIR DUCTING Fig. 1 The stove, in the models confi gured for ducting, features 2 centrifugal fans suitable for channelling the air in the adjacent rooms. As standard, the air comes out of the grilles placed laterally with an air fl ow of 45° with respect to the front. (Fig. 1) Fig. 2 By rotating the fan it is possible to exit from the back of the stove with a ducting air pipe with a 60mm diameter.
  • Page 29 18 3RD TANGENTIAL FAN Fixing screws WIRING DIAGRAM AMB. EXCHANG. 08/2020 - EN...
  • Page 30 LEGEND PRODUCT LABEL ITALIANO ENGLISH DEUTSCH FRANCAIS ESPAÑOL Combustibile Fuel type Brennstoff Combustible Combustible Max. Potenza termica nomi- Nominal space heat Puissance nominale Potencia nominal Raumnennwärmelei- nale all’ambiente output a l’aìr a la aìre stung Potenza termica ridotta Reduced space heat Puissance partielle Potencia parcial Raumteilwärmeleistung...
  • Page 31: Wiring Diagrams

    WIRING DIAGRAMS LCD PANEL JP27 JP26 JP23 PC/WiFi Fume M. Encoder Earth Faston Auger M. Encoder 3VDC CR2032 Delivery/Amb Probe TA/Chrono/GSM inp. Ducted 1 Probe J JP24 JP14 JP16 JP25 SW 3 SW 3 Tank Thermost. Tank Thermost. SW 2 SW 2 Fume Pressure ITALIANO...
  • Page 32 FANCY 12 DESCRIPTION ITALIANO ENGLISH FRANCAIS DEUTSCH ESPAÑOL Coperchio serbatoio Pellet lid Couvercle du reservoir Behaelterabdeckung Tapa del tanque Portina focolare Firebox door Porte foyer Feuertuer Puerta del hogar Vetro portina Glass panel Vitre porte Glastuer Vidrio puerta Maniglia di apertura...
  • Page 33: Technical Features

    FANCY 12 TECHNICAL FEATURES Thermal heat input 5,1 kW 12 kW 4128 kcal/h 10234 kcal/h Overall thermal heat (yield) 4,8 kW 10,5 kW Yield 93,2 % 87,2 % Fume temperature 101,5 °C 218,3 °C Fume flow rate 3,88 g/s 7,10 g/s Hourly fuel consumption...
  • Page 34 SCOOP REMOVAL MINIMUM DISTANCE FROM COMBUSTIBLE MATERIALS [cm] Product images are purely indicative 08/2020 - EN...
  • Page 35 FANCY 12 DIMENSIONS 565,1 Dimensions (mm) 08/2020 - EN...
  • Page 36 CERTIFICAZIONI CERTIFICAZIONI CERTIFICATIONS CERTIFICATIONS ZERTIFIZIERUNGEN ZERTIFIZIERUNGEN CERTIFICATIONS CERTIFICATIONS CERTIFICACIONES CERTIFICACIONES 08/2020 - EN...
  • Page 37 FANCY 12 08/2020 - EN...
  • Page 38 FANCY 12 08/2020 - EN...
  • Page 39 FANCY 12 08/2020 - EN...
  • Page 40 TERMOVANA by Delka Via Crevada, 63 31020 Refrontolo (TV) Italy Tel. +39 0438 1672066 Fax +39 0438 1672067 e-mail: info@termovana.it www.termovana.it La Ditta DELKA non si assume alcuna responsabilità per eventuali errori del presente opuscolo e si ritiene libera di variare senza preavviso le caratteristiche dei propri prodotti.

Table of Contents