8. TROUBLESHOOTING

If these solutions, below, do not work, contact your dealer.
Do not attempt to repair the heater yourself.
Failure
Reason
Main power off
Swimming
Power switch
Pool Heat
is off
Pump Does
Fuse burnt
Not Run
Circuit breaker
tripped
Air inlet blocked
Air outlet
Heat Pump
blocked
Runs but
Does Not
3-minute
Heat
protection
Temp set too
low
Table G.
Common Faults

Fault Codes

Failure Code
E1
High pressure protection
E2
Low pressure protection
E3
Low water pressure protection
Single phase unit: loose wire terminal at
PROT2 on the PC board
E4
Three phase unit: 3 phase sequence
protection
P1
Pool water temp sensor failure
Exhaust temp sensor failure (cooling coil
P2
temp for heat and cooling models only)
P3
Heating coil pipe temp sensor failure
P4
Gas return temp sensor failure
P5
Air temp sensor failure
Compressor exhaust overload protection
E6
212°F (100°C) (Heating models only)
When air temp <32°F (0°C), the unit is in
P7
auto-stop protection mode, or anti-freeze
mode (not a failure)
HEAT flashing Defrosting (not a failure)
Table H.
Fault Codes - On/Off Models Only
26
Solution
Wait for the power to be
restored
Turn on switch
Replace fuse
Turn circuit breaker back on
Remove obstructions
Remove obstructions
Please wait more than 3
minutes for warming to start
Set temperature setting
Failure Description
No.
Display
1
E3
No water protection
2
E5
Power supply excesses operation range
Excessive temp difference between inlet
3
E6
and outlet water
(insufficient water flow protection)
Ambient temperature too high or too low
4
Eb
protection
5
Ed
Anti-freezing reminder
No.
Display
1
E1
High pressure protection
2
E2
Low pressure protection
3 phase sequence protection
3
E4
(three phase only)
Water outlet temp too high or too low
4
E7
protection
5
E8
High exhaust temp protection
Evaporator overheat protection
6
EA
(only at cooling mode)
7
P0
Controller communication failure
8
P1
Water inlet temp sensor failure
9
P2
Water outlet temp sensor failure
10
P3
Gas exhaust temp sensor failure
11
P4
Evaporator coil pipe temp sensor failure
12
P5
Gas return temp sensor failure
13
P6
Cooling coil pipe temp sensor failure
14
P7
Ambient temp sensor failure
15
P8
Cooling plate sensor failure
16
P9
Current sensor failure
17
PA
Restart memory failure
18
F1
Compressor drive module failure
19
F2
PFC module failure
20
F3
Compressor start failure
21
F4
Compressor running failure
22
F5
Inverter board over current protection
23
F6
Inverter board overheat protection
24
F7
Current protection
25
F8
Cooling plate overheat protection
26
F9
Fan motor failure
27
Fb
Power filter plate no-power protection
28
FA
PFC module over current protection
Table I.
Fault Codes - Inverter Models Only