Electrical Check - Sony MHC-V6D Service Manual

Hide thumbs Also See for MHC-V6D:
Table of Contents

Advertisement

TUNER SECTION
0 dB = 1 V
FM TUNE LEVEL CHECK
signal
generator
unit
Procedure:
1. Press the [
/
] button to turn the power on.
?
1
2. Input the following signal from signal generator to FM antenna
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the unit.
You cannot use video cable for checking.
Use signal generator whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confi rm "TUNED" is lit on the display for A, B and C signals.
When the selected station signal is received in good condition,
"TUNED" is displayed.