LMI Technologies LCI1220 User Manual

LMI Technologies LCI1220 User Manual

Focalspec line confocal sensors

Advertisement

FOCALSPEC LINE CONFOCAL SENSORS
LCI1220 & LCI1620
USER GUIDE
Version 1.2

Advertisement

Table of Contents
loading

Summary of Contents for LMI Technologies LCI1220

  • Page 1 FOCALSPEC LINE CONFOCAL SENSORS LCI1220 & LCI1620 USER GUIDE Version 1.2...
  • Page 2 LMI Technologies, Inc. Trademarks and Restrictions FocalSpec™ is a registered trademark of LMI Technologies, Inc. Any other company or product names mentioned herein may be trademarks of their respective owners. Information contained within this manual is subject to change.
  • Page 3 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 2/31 Version history Version Status Date Author Comments Approved 27.2.2020 Kalistaja A note added to 5 David Connecting to PC. Aligned spec terminology with datasheet / LMI. Approved 22.1.2020 David Rebranding Approved 30.9.2019 Esa Kalistaja First version LMI Technologies, Inc.
  • Page 4: Table Of Contents

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 3/31 CONTENTS 1 About this Document ..................... 4 2 Safety Information ......................4 2.1 Safety Notes 2.2 Warnings 2.3 Proper Use 2.4 CE Marking 3 Technical Data ........................ 6 4 Delivery Contents ......................6 5 Connecting to PC ......................
  • Page 5: About This Document

    4/31 1 About this Document This document is user guide of sensors LCI1220 and LCI1620. Sensors LCI401, LCI1200, LCI1201 and LCI1600 are covered by separate guide. FocalSpec Software Development Kit (FSSDK) and the API documentation can be found after FSSDK installation from folder: C:\Focalspec\FocalSpec Software Development Kit\Manual.
  • Page 6: Proper Use

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 5/31 2.3 Proper Use The LCI sensor is designed for the use in industrial areas. The sensor is used for optical measurements, such as 3D topography, dimensions and distances measurements, measuring the tomography of transparent materials, surface micro profile measurements, and film thickness measurements.
  • Page 7: Technical Data

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 6/31 3 Technical Data Table 1. Technical data for the sensors LCI 1220 LCI 1620 Field of view 11.6 17.0 mm X resolution 9.9 µm Z repeatability* 0.19 0.25 µm Stand-off distance 20.6 64.00 mm Measurement range 3.00...
  • Page 8: Connecting To Pc

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 7/31 5 Connecting to PC 10 Gbit connection with SFP+ interface is needed to enable the high-speed data transmission. The recommended network adapter is Intel Ethernet Converged Network Adapter X520 either two port DA2 or four port DA4 model.
  • Page 9 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 8/31 Figure 2. Installation and mounting of LCI1220. LMI Technologies, Inc. • www.lmi3d.com...
  • Page 10 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 9/31 Figure 3. Installation and mounting of LCI1620. LMI Technologies, Inc. • www.lmi3d.com...
  • Page 11: Handling Optical Cable And Sfp+ Modules

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 10/31 7 Handling Optical Cable and SFP+ Modules IMPORTANT – FRAGILE Minimum bending radius of optical cable is 100 mm. Don’t bend cable more than this. This applies to the whole length of the cable and it is especially important to pay attention to computer end of the cable as it is more flexible.
  • Page 12: Installing Sfp+ Module And Optical Cable

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 11/31 Figure 4: Minimum bending radius of the optical cable is 100 mm 7.2 Installing SFP+ Module and Optical Cable Steps to install the optical cable and SFP+ module: 1. Remove protective plug from SFP+ module.
  • Page 13: Detaching Sfp+ Module From Optical Cable

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 12/31 have a lock. Having the lock readily in the open position enables quick and easy attaching of the SFP+ module. 4. Carefully insert the cable connector to SFP+ module. Push the connector gently until it locks in place (step 2).
  • Page 14: Electrical Connections

    13/31 8 Electrical Connections LCI1220 and LCI1620 sensors are powered by using a PushPull type 4-pin cable with Harting Power connector. For input signals which can be used for synchronization purposes 10-pin PushPull type cables with Harting Signal Connectors is used. The sensor communicates with PC via Optical cable with SFP+ 10G transceiver modules.
  • Page 15 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 14/31 Figure 7. Electrical connections for LCI1620 (I/O 2 connector is not in-use at the moment) There are three indicator LEDs next to the connectors on the connector panel. The status LED turns red if the sensor is not connected to a PC or a router. Blue means SW is booting up, whereas a green light indicates that the connection is established.
  • Page 16 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 15/31 Table 2. Indicator LEDs LMI Technologies, Inc. • www.lmi3d.com...
  • Page 17: Input And Output Description

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 16/31 9 Input and Output Description Table 3. Power cable pinout Color Name Description 24VDC 24 V (21 V – 28 V) / 2.3 A 24VDC Power Ground Red ring Cable Cable shield (connect to...
  • Page 18 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 17/31 Table 4. Signal cable pinout (pins 5 to 7 not in use till later SW update) Color Name Description White Input GND Common ground for inputs Brown Input 1 Input 1 (5V & 24 V,...
  • Page 19 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 18/31 Input / Output Parameter Value Sensor Power supply voltage (recommended) 24VDC Power supply unit requirements (PSU): 24VDC@4A Input signal voltage (operating range) 3.5V - 26V Input signal Maximum pulse rate 150 kHz Input signal current Min 2.7 mA...
  • Page 20 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 19/31 Figure 11. Optical cable SFP+ module LMI Technologies, Inc. • www.lmi3d.com...
  • Page 21 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 20/31 Figure 12. Example wiring for sensor connection NOTE 1: Connect the power cable ring terminal to system GND NOTE 2: Ensure that the sensor mount has the same ground potential as the sensor itself.
  • Page 22: External Trigger Configurations

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 21/31 10 External Trigger Configurations The trigger inputs can be used to synchronize the sensor with an external device. Application examples include: synchronizing the profile measurement into a certain signal of a production process or combining profiles into 3D point clouds based on the trigger index. Enabling external and internal triggering is explained in the “FocalSpec Software Development Kit”.
  • Page 23: Sensor Warming Up

    • The target on the reference sample holder must not be touched. Keep the sample clean and if needed, use compressed air for cleaning, do not use liquid, etc. Figure 15. Reference sample holders of LCI1220 (left) and LCI1620. LMI Technologies, Inc. • www.lmi3d.com...
  • Page 24: Getting Started

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 23/31 13 Getting Started This chapter gives instructions on how to set up the system with the sensor and a PC in order to show measurement profile. Step Illustration Instructions Lay down the sensor...
  • Page 25 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 24/31 Remove dust caps from POWER, I/O 1 and Ethernet. Power and I/O caps are connected to sensor. Ethernet cap is loose, store it for possible future use. Dust caps removed from POWER, I/O 1 and Ethernet.
  • Page 26 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 25/31 Lock connector turning the yellow ring clock-wise. Before connecting the power, test that power source voltage setting is the correct 24V. Plug in 4-pin power connector. Yellow marks indicate correct orientation. Remove dust cap from the...
  • Page 27 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 26/31 Attach a reference sample holder on the magnet on the casing of the sensor. Do not touch the lenses or the black pipes. Power on the sensor. Sensor starting up takes about 30 seconds.
  • Page 28 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 27/31 Make sure the network adapter of the PC to set to obtain IP address automatically: 1. Go back to Properties. 2. Double-click Internet Protocol Version 4 (TCP/IPv4) on the list. 3. Ensure Obtain an IP address automatically is selected as depicted on the left.
  • Page 29 2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 28/31 When the installation is completed: Turn on the sensor power, wait until the power LED indicator is green. Start FocalSpec GUI Example Application by double-clicking the shortcut on desktop. The application controls are explained...
  • Page 30: Troubleshooting

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 29/31 14 Troubleshooting Q: An application cannot find any sensors. SDK function Open () returns 0 sensors. A: Network troubleshooting checklist: 1. Check that the application binaries (.exe and vshost.exe) are allowed in firewall a.
  • Page 31: Support

    2020-03-10 FOCALSPEC User guide LCI1220-1620 v1.2 30/31 f. If the problem still exists, do the following: power off the sensor, close the PC software, power on the sensor and start the PC software. 4. Change LED Pulse Width [µs] back to a more reasonable value. To validate, monitor Average Intensity text box, which indicates if LED Pulse Width [µs] is too low, ok, or...