Configuration.xml
3HAC031973-001 Revision: F
<MaxLost>30</MaxLost>
<DryRun>false</DryRun>
</Settings>
</Description>
<?xml version="1.0" encoding="utf-8" ?>
<Configuration>
<Enums>
<Enum Name="OperationMode" Link="Intern">
<Member Name="Automatic" Alias="Auto" />
<Member Name="ReducedSpeed" Alias="ManRS" />
<Member Name="FullSpeed" Alias="ManFS" />
</Enum>
</Enums>
<Records>
<Record Name="RobotData">
<Field Name="OperationMode" Type="OperationMode" Link="Intern"
Alias="RobMode" />
<Field Name="FeedbackTime" Type="Time" Link="Intern"
Alias="Ts_act" />
<Field Name="FeedbackPose" Type="Frame" Link="Intern"
Alias="P_act" />
<Field Name="FeedbackJoints" Type="Joints" Link="Intern"
Alias="J_act" />
<Field Name="PredictedTime" Type="Time" Link="Intern"
Alias="Ts_des" />
<Field Name="PlannedPose" Type="Frame" Link="Intern"
Alias="P_des" />
<Field Name="PlannedJoints" Type="Joints" Link="Intern"
Alias="J_des" />
<Field Name="ApplicationData" Type="Num" Size="18"
Alias="AppData" />
</Record>
<Record Name="SensorData">
<Field Name="ErrorString" Type="String" Alias="EStr" />
<Field Name="ApplicationData" Type="Num" Size="18"
Alias="AppData" />
</Record>
</Records>
<Properties>
<Property Name="RobData" Type="RobotData" Flag="WriteOnly"/>
<Property Name="SensData" Type="SensorData" Flag="ReadOnly"/>
</Properties>
</Configuration>
© Copyright 2008-2009,2013 ABB. All rights reserved.
4 Configuration examples
4.2 Example configuration
Continued
Continues on next page
29