Mini-SD-HME is a mini-sized wireless smoke detector with built-in PIR motion sensor, heat detector and emergency light.
Mini-SD-HME is designed to protect your family against potential fire hazard.

Parts Identification

1. IR lens
2. LED Indicator & Learn/Test Button/Emergency Light
Red LED
 Quick flash: Alarming
 Flashes every 1 second: Sleep Mode.
 Flashes every 2 seconds: Under warmup and calibration process.
 Flashes every 4 seconds with Orange LED: battery exhausted.
 Flashes briefly: When Learn Button is pressed to see if the device is functioning normally.
 Lights up briefly: Transmitting signal.
 Flashes 2 times: When receiving acknowledgement from the Control Panel.
Orange LED
 Flashes every 4 seconds with RED LED: battery exhausted.
 Flashes every 5 seconds: Calibration Failure
 Flashes every 45 seconds: Low battery condition
Learn/Test Button
 Press the button once to:
 Send a supervision / test signal.
 Check smoke detection chamber.
 Silence alarm.
Emergency Light
 The emergency light will be turned on simultaneously when an alarm is triggered.
3. Buzzer
4. Mounting Holes
5. Battery compartment
6. Hooks
7. Mounting Holes

Getting Started

Step 1. Put the Control Panel into learning mode. Refer to the Control Panel manual for details.
Step 2. Insert battery to power on the Mini Smoke Detector.
Step 3. The Mini Smoke Detector will emit 2 short beeps and begin warm up for 1 minute. The Red LED will flash
every 2 seconds.
Step 4. During the 1 minute period, press the Learn/Test button once to transmit learn code. The Mini Smoke
Detector will emit a 2-tone beep. Refer to Control Panel manual to complete learning process.
Step 5. When the Mini Smoke Detector completes warm-up, it will emit a beep to indicate it has entered
calibration mode. The calibration mode lasts for 1~9 minutes. The Red LED will continue to flash every
two seconds during calibration. Learning the Mini Smoke Detector is prohibited during this period.
Step 6. When calibration is completed, the Mini Smoke Detector will emit 2 short beeps and turn off LED to return
to normal mode. If the Mini Smoke Detector is not learnt into panel previously, press the Learn/Test button
now to complete learning.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini-SD-HME and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climax Technology Mini-SD-HME

  • Page 1 Mini Smoke Detector (Mini-SD-HME) User Manual Mini-SD-HME is a mini-sized wireless smoke detector with built-in PIR motion sensor, heat detector and emergency light. Mini-SD-HME is designed to protect your family against potential fire hazard. Parts Identification 1. IR lens 2. LED Indicator & Learn/Test Button/Emergency Light Red LED ...
  • Page 2 LED indicator will flash every time a movement is detected.  ACK  After the test button is pressed for one time, if the Mini-SD-HME receives acknowledgement from the Control Panel, the Red LED will flash 4 times followed by two beeps. If the Mini-SD-HME does not receive acknowledgement from the Control Panel, the Red LED will flash 8 times followed by two beeps.
  • Page 3  During the 9-minute Alarm Silence period, the Red LED will flash once per second. The Smoke Detector will continue to monitor smoke concentration during the alarm silence period:  After the 9-minute Alarm Silence period has expired, if the smoke concentration has dropped below alarm threshold, the Smoke Detector will emit a 2-tone beep and return to normal operation without sounding alarm.
  • Page 4 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Table of Contents