SD-29 series is a mini-sized wireless smoke detector with built-in PIR motion sensor, temperature sensor and emergency light (optional).
Designed to protect your family against potential fire hazards, the Smoke detector is also capable of detecting movements and reporting
temperature to users. The Z-Wave Smoke Detector allows access to the "S2 Unauthenticated" class.
The SD-29 is a wirelessly operated photo-electronic Smoke Detector designed to operate with any Z-Wave enabled controller devices; it also
features smoke detecting, temperature sensing and IR detection. The Smoke Detector's alarm situations, battery condition, operating conditions,
supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected
with other sensors in the Z-Wave gateway to serve as an extra siren.
The Smoke Detector is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave is a wireless
communication protocol that uses a low-power RF radio. By taking advantage of the Z-Wave mesh network, commands can be transmitted to
their destination via intermediary "listening" Z-Wave products.
The Smoke Detector calibrates for the air contents after warming up to determine a standard condition for the environment. It can also be
manually instructed to calibrate for air content. It is also pre-programmed to automatically calibrate once a month.
The Smoke Detector includes the following models:
Model Name
SD-29
SD-29-T
SD-29-M
SD-29-TM
SD-29-TME
P
a
r
t
s
I
d
e
n
t
i
f
i
c
a
t
i
o
P
a
r
t
s
I
d
e
n
t
i
f
i
c
a
t
i
o
1. LED Indicator /Function Button / Emergency Light
Red LED
 Turns ON briefly: Transmitting signal.
 Quick flash: Alarming.
 Flashes every 1 second: Smoke Detector under Sleep Mode
 Flashes every 2 seconds: Smoke Detector under warmup and calibration process.
 Flashes every 4 seconds: battery exhausted.
Orange LED
 Flash every second: Device power on/Calibration failed.
 Flashes every 5 seconds: Detecting smoke failed or device malfunctioning.
 Flashes every 4 seconds: battery exhausted.
 Flashes every 45 seconds: Low battery condition
Function Button
 Press the button once to send test signal.
 Press the button once during alarm to silence the alarm.
 Press the button twice to discharge before inserting new batteries.
 Press the button 3 times within 1.5 seconds to send a learn code.
 Press and hold the button for 10 seconds to enter calibration process.
 Press and hold the button for 20 seconds to perform factory reset.
White LED (Emergency Light)
 The emergency light will begin to flash slowly to alert uses that the system is alarming. (SD-29-TME only)

2. IR Lens

3. Buzzer

k
e
D
e
t
e
c
t
o
r
S
k
e
D
e
t
e
c
t
o
r
S
Smoke Detection
O
O
O
O
O
n
n
e
r
i
e
s
e
r
i
e
s
Temperature Sensor
O
O
O
1
PIR Sensor
Emergency Light
O
O
O
O

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD-29 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climax Technology SD-29 Series

  • Page 1 SD-29 series is a mini-sized wireless smoke detector with built-in PIR motion sensor, temperature sensor and emergency light (optional). Designed to protect your family against potential fire hazards, the Smoke detector is also capable of detecting movements and reporting temperature to users. The Z-Wave Smoke Detector allows access to the “S2 Unauthenticated” class.
  • Page 2 5. Battery compartment 6. Hooks 7. Mounting Bracket 8. Mounting Holes (for Hooks) The Hooks of the Mounting Bracket can hook into this Mounting Hole. 9. Mounting Sheet    Three 3V CR123 Lithium batteries are used to supply power to the Smoke Detector. ...
  • Page 3  After the 9-minute Alarm Silence period has expired, if the smoke concentration has dropped below alarm threshold, the Smoke Detector will emit a 2-tone beep and return to normal operation without sounding alarm.  If smoke concentration still exceeds alarm threshold, the Smoke Detector will start alarming again. ...
  • Page 4   The Smoke Detector must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device. Exclusion Mode  Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual). ...
  • Page 5  The Smoke Detector is designed to be mounted on the ceiling. The ideal mounting height for the Smoke Detector is 2.7 meters to 3 meters. Mounting above 3 meters can affect detection performace. (SD-29-M/SD-29-TM/SD-29-TME only)  The Smoke Detector can support detection coverage within a radius of 4 meters. Please refer to below figures for the installation details.
  • Page 6   Device Type: Sensor – Notification Smoke Alarm Role Type: Listening Sleeping Slave (LSS) Max Association Group: 2 Command Class Support/Control Mandatory CC Support: Z-Wave Plus Info CC Association CC, (S2) Multi Channel Association, (S2) Association Group Information CC, (S2) Transport Service CC Version CC, (S2) Manufacturer Specific CC, (S2)
  • Page 7  Temperature Report: [COMMAND_CLASS_SENSOR_MULTILEVEL] [SENSOR_MULTILEVEL_REPORT]  The Smoke Detector can report temperature signal to the Control Panel every 30 to 33 minutes with Smoke Detector normal operating or when temperature changes by +/- 2°C.  Temperature: 01 22 00 FA Sensor Type : 0x01 Size : 2 Scale : 0...

This manual is also suitable for:

Sd-29Sd-29-tSd-29-mSd-29-tmSd-29-tme

Table of Contents