Smoke and Carbon Monoxide Detector
(SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC)

Introduction

SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC is a Z-Wave Smoke and Carbon Monoxide Detector with
temperature, humidity, and heat detection, as well as voice prompts and allows access to the "S2 Unauthenticated" class. It is
capable of sending wireless signals to the Z-Wave gateway/control panel upon detection of smoke particles or Carbon Monoxide.
The device is also serially connected with other sensors in the Z-Wave gateway to serve as an extra siren. When any other
sensor in the Z-Wave network is activated and sends an alarm signal, the Smoke Detector will also raise alarm with its built-in
buzzer as a siren to help sound warning (for serial connection models).
The SDCO-1 is designed to be mounted on ceiling or top of stairwells when smoke would concentrate to raise alarm timely and
protect your home from fire hazards.
The SDCO is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave is a wireless
communication protocol that uses a low-power RF radio.

Parts Identification

1. Speaker
2. Button
 Press the button once to send an alarm test, temperature and humidity signals / test Smoke and Carbon Monoxide Detector.
 Press the button once during alarm to silence the alarm.
 Press the button 3 times within 1.5 seconds to send an inclusion code.
 Press and hold the button for 10 seconds. Release the button when you hear 2 beeps to enter smoke calibration and CO self-diagnosis
.process.
 Press and hold the button for 20 seconds. Release the button when you hear 3 beeps to perform factory reset.
 Press the button twice before inserting new batteries.
3. LED Indicator
Red LED
 Turns ON briefly: Transmitting signal.
 Quick flash: Alarming.
 Flashes every second: In Alarm Silence Mode.
 Flashes every 2 seconds: Under warmup and calibration process.
Amber LED
 Flash every second: Device power on/Calibration failed.
 Flashes every 5 seconds: Auto-calibration/self-diagnostic has failed.
 Flashes every 45 seconds: Low battery condition
Both Red and Amber LED (Orange when looking from the outside)
 Turns ON: Temperature/ Humidity sensor failed.
 Flashes every 4 seconds: Battery exhausted.
4. Buzzer
5. Mounting Holes (for Hooks)
The Hooks of the Mounting Bracket can hook into this Mounting Hole.
6. Mounting Bracket
7. Internal Tamper
8. Battery Compartment Cover
9. Battery Switch
10. Pre Punched Hole for Wiring
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDCO-1-RhTH-ZW-SC-AC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Climax Technology SDCO-1-RhTH-ZW-SC-AC

  • Page 1 (SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC) Introduction SDCO-1-RhTH-ZW-SC-AC/SDCO-1-RhTH-ZW-SC-OTA-AC is a Z-Wave Smoke and Carbon Monoxide Detector with temperature, humidity, and heat detection, as well as voice prompts and allows access to the “S2 Unauthenticated” class. It is capable of sending wireless signals to the Z-Wave gateway/control panel upon detection of smoke particles or Carbon Monoxide.
  • Page 2  Battery and Low Battery Detection  The SDCO-1-RhTH-ZW-SC-AC model uses AC 100-240V as its power source and has three 600mAh AAA Ni-MH rechargeable batteries as its backup battery in case of power failure. The battery is included in the package.
  • Page 3  Removing Device (Exclusion) The SDCO must be removed from existing Z-Wave network before being included into another.  Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).  Within 1.5 seconds, press the button 3 times and the SDCO will be removed from the Z-Wave network. ...
  • Page 4 Beep---Beep---Beep---Beep-Beep-Beep-Beep----- alarm is detected. Please note the location Beep---Beep---Beep prompt will be played according to the preprogrammed location name. Emergency, Smoke in [location name]. Location. Evacuate. Emergency, Carbon Monoxide in [location name]. Location. Evacuate.  Alarm Detection The SDCO Detector will activate fire alarm when either of its smoke detection or high heat detection function is triggered. When an alarm is activated, the SDCO Detector will transmit alarm signal and raise alarm with its built in buzzer, the Red LED will flash rapidly.
  • Page 5 If smoke concentration continues to rise during Alarm Silence period and exceeds a second alarm threshold, the SDCO will start alarming again. An alarm activated by exceeding the second alarm threshold could not be silenced by pressing the button.  Recalibration The SDCO will calibrate its smoke detector sensor every time when power is applied to ensure optimal smoke sensitivity.
  • Page 6 Figure 1 Figure 2 Step 6. Repeat Step 4 and Step 5 to insert the black wire. Insert the white and black wire to the same side (right) as shown below, of the two connectors allows you an easier installation in the following steps. Step 7.
  • Page 7 Z-Wave Information Device Type: Sensor Notification Smoke Alarm Role Type: Always On Slave (AOS) Max Association Group: 2 Command Class Support/Control Mandatory CC Support: Z-Wave Plus Info CC Association CC, (S2) Multi Channel Association CC, (S2) Association Group Information CC, (S2) Transport Service CC Version CC, (S2) Manufacturer Specific CC, (S2)
  • Page 8  Temperature: 01 42 09 D1  If temperature signal 01 42 09 D1 is transmitted: 09D1 can be viewed as 0x09D1 in Hexadecimal number. You can convert hexadecimal to decimal and divide by 100 to check the temperature data (in Celsius). 0x09D1=2513=25.13℃.

This manual is also suitable for:

Sdco-1-rhth-zw-sc-ota-acSdco-1Sdco-1-rhth-zw-sc

Table of Contents