1. DESCRIPTION
The bus push button is in fact a 3-position switch: there is always a top
position, a bottom position and a middle position (neutral). The bus push
buttons have the familiar design of a Niko switch. However, they do not
function as conventional switches, but as data transmitters.
A Nikobus push button is mounted into a simple standard flush mounting
box that is suitable for screw fixing. For mounting under multiple flush
surround frames, no additional flush mounting boxes are required. The
Nikobus push buttons can be extended without additional drilling or duct-
ing. Moreover, the Nikobus push button does not require any adjustment.
The functions of the push buttons are not determined by the push buttons
themselves, but by the installer's settings on the module. When setting the
system, the functions of the bus push buttons are assigned by controlling
the buttons. When activating, a telegram is sent to the module via the bus.
The telegram carries the bus push button's address and the information
on what is to be carried out. The telegram is sent by current modulation. If
the bus push button is pressed for over 8s., the telegram is automatically
interrupted and the bus is released.
2. TECHNICAL DATA
Ambient temperature: 0 to +50°C
Bus voltage : 9V DC (SELV, safety extra low voltage)
Address: 22 bit (± 4 million different codes possible)
Max. operating time: 8s.
Connection to the Nikobus: 2-wire connection
3. INSTALLATION
A Nikobus push button can be screwed onto a simple standard flush
mounting box, irrespective of the use of a simple or multiple PCB. The bus
push button is mounted on the PCB by means of a central screw. Contact
springs at the rear side of the bus push buttons provide the electrical
contact between the PCB and the push buttons. The PCB is connected to
the bus by means of a connector at its rear side. This enables to unscrew
the bus push buttons without disconnecting the bus wires.
4. LEGAL WARNINGS
- The installation has to be carried out by a qualified person and in compli-
ance with the statutory regulations.
- This user manual has to be handed over to the user. It has to be included
in the electrical installation file and has to be passed on to any new
owners. Additional copies are available on the Niko website or via the
support service.
- During installation, the following has to be taken into account (not limited
to list below):
- The statutory laws, standards and regulations;
- The state of the art technique at the moment of installation;
- This user manual, which must be read within the scope of each specific
installation, only states general regulations;
- The rules of proper workmanship
- In case of questions, you can consult Niko's support service or contact
a registered control organisation.
Support Belgium:
Support UK:
+32 3 778 90 80
+44 1525877707
website : http://www.niko.be
http://www.nikouk.com
e-mail: support@niko.be
sales@nikouk.com
In case of a defect, you can return your product to a registered Niko
wholesaler, together with a clear description of your complaint (Conditions
of use, stated defect...).
5. GUARANTEE PROVISIONS
- Period of guarantee: 2 years from date of delivery. The delivery date is
the invoice date of purchase of the product by the consumer. If there is
no invoice, the date of production applies.
- The consumer is obliged to inform Niko in writing about the defect, within
two months after stating the defect.
- In case of a failure to conform, the consumer has the right to a repair or
replacement (decided by Niko) free of charge.
- Niko cannot be held liable for a defect or damage as a result of an incorrect
installation, improper or careless use or wrong usage or transformation
of the goods.
- The compulsory regulations of the national legislation concerning the
sales of consumer goods and the protection of the consumers in the
countries where Niko sells, directly or via sister or daughter companies,
chain stores, distributors, agents or permanent sales representatives,
take priority over the rules and regulations mentioned above.
nv Niko sa
There are 5 types of push buttons with variants of rockers:
• 05-060-01: bus push button with 2 keys for rocker with or without text field
+
• 05-061-01: bus push button with 2 keys + LED for rocker with lens
+
• 05-064-01: bus push button with 4 keys for 2 x 1/2 rocker with or without text field
+
• 05-074-01: bus push button with 4 keys for 2 x 1/2 rocker with feedback LED for regimes
+
• 05-078-01: bus push button with 8 keys for 8 rockers
+
Installation
Wiring diagram IR push buttons
connection for
power supply
Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@Niko.be — www.niko.be
or
or
or
or
or
or
or
or
or
or
or
or
bus connection
T O P
450-00021
wall-mounted PCB (e.g.: 450-00021)
or
or
or
or
or
or
or
or
or
PM005-06001R08163

Advertisement

loading

This manual is also suitable for:

05-061-0105-064-0105-074-0105-078-01