Download Print this page

Bestway Lay-Z-Spa 54138 Manual page 11

Hide thumbs Also See for Lay-Z-Spa 54138:

Advertisement

A
Lock/Unlock Button
The pump has a 5-minute auto-lock. The LED light will dim out when the pump
is locked (no function is activated).To lock or unlock the pump, place a finger
over the lock/unlock button for 3 seconds.
B
Lay-Z-Massage System Button (For Hydro-Jet Pro)
Use this button to activate the massage system, which has a 30-minute
auto-shutoff feature.
The light above the Lay-Z-Massage system button displays red when activated.
IMPORTANT: Do not run the Lay-Z-Massage system when the
cover is attached. Air can accumulate inside the spa and cause
irreparable damage to the cover and bodily harm.
NOTE: Heat and massage system work together to create a warm
massage experience.
C
HydroJet System Button
This button turns the water pump on and off.
The light above the HydroJet system button displays red when activated.
Note: The system will shut off automatically after 1 hour.
Note: Do not dry run the HydroJet System.
D
Heat Button
Use this button to activate the heating system. When the light above the heat button
is red, the heating system is activated. When the light is green, the water is at the set
temperature and the heating system is at rest.
NOTE: If the heating system is activated, the filtration system will automatically start.
NOTE: After turning off the heating system, the filtration system will continue to operate.
E
Water Filter Button
This button turns the filter pump on and off.
The light above the Water Filter Button displays red when activated.
NOTE: The built-in hard water treatment function works automatically.
F
Salt Chlorinator System Button
Use this button to turn on the Salt Chlorinator System and set the working duration.
You can set the working duration from 3 hours to 5 hours to 8 hours by pushing the
Salt Chlorinator System Button. After setting the working duration, the Salt Chlorinator
System will start to work automatically.
NOTE: Do not press any buttons on the panel and attach the SPA cover during the chlorinating
progress. You can re-adjust the working duration by pushing the Salt Chlorinator System Button.
NOTE: Test the water regularly and make sure the free chlorine level is between 2-4 ppm.
G
Power-Saving Timer Button
This is a newly added function, designed to help avoid wasting power by setting the
time and duration of the heating cycle for the spa.
This way, you can enjoy your spa at the time you desire, without needing to leave the
heater on at all times.
STEP 1: Set the heating duration
1. Press the
button unit the
LED starts to flash.
2. Press the
or
button to adjust the heating duration (From 1-48 hours).
3. Press the
button again to confirm the heating duration.
STEP 2: Set the number of hours FROM NOW when the heater will activate
1. After setting the heating duration, the
2. Press the
or
button to adjust the hours until time of activation (From 0-99 hours).
3. Press
button again or simply touch nothing for 10 seconds to confirm the setting.The
will light steadily, and the countdown to heater activation will begin.
To modify the timer settings: Press the
Cancel the setting: Press the
button for 2 seconds.
Alarms
Causes
The water flow sensors work
without pressing the filter or heat
button.
After starting or during the
functions of filtering or/and
heating, the water flow sensors
do not detect water flow.
The pump's
thermometer reads the water
temperature below 4°C (40°F).
The pump's thermometer reads
the water temperature over
50°C (122°F).
The pump's
thermometer
connections have issues.
The manual reset thermal
cut-out has a problem.
104°C (219°F) Fuse fault.
Hign salt alarm.
Low salt alarm.
Water leakage inside the pump.
Signal line disconnected.
S-S-004815/21x28.5cm/54138AU, 54144AU 澳规SPA说明书/JS-YF-2016-B-06737/英
LED starts to flash.
LED
button and use the
or
button to adjust.
Reasons
1. The water flow sensor flag didn't fall back into
the correct position.
2. The water flow sensors are broken.
1. You forgot to remove the 2 stopper caps from inside
the pool.
2. The filter cartridges are dirty.
3. Activate the filter or heat system and put your hand
in front of the outlet pipe inside the pool to check if
you can feel water. flowing out.
a. If no water flows out the water pump is broken.
b. Water flows out but the alarm
water flow sensors are broken.
1. The water temperature is lower than 4°C (40°F).
2. If the water temperature is higher than
7°C (44.6°F), the pump's thermometer is broken.
1. The water temperature is over 50°C (122°F).
2. If the water temperature is lower than
45°C (113°F), the pump's thermometer is broken.
1. The pump's thermometer connectors are not
working properly.
2. The pump's thermometer is broken.
The manual reset thermal cut-out has been tripped.
The fuse is disconnected.
Too much salt has been added or too much water
has evaporated.
Not enough salt for sanitizing.
The system has detected some water leakage inside
the pump.
The signal line between control panel and power board
is not well connected.
HYDROJET PRO
NOTE: After setting, the screen flashes the current temperature and time alternately.
NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 48 hours; Reservation
time adjustment (the number of hours FROM NOW when the heater will begin to function) may be set from
0 to 99 hours. If the timer is set at 0 hour, it means the Timer function is not set.
Note that the timer is one time per use - the user sets the duration of the heating cycle, and how many hours
from now the heating cycle begins. The timer does NOT repeat until reset.
H
Celsius/Fahrenheit Toggle
The temperature can be displayed in either Celsius or Fahrenheit.
I
Temperature Adjustment Buttons
Pressing the Temperature Increase or Decrease buttons will cause the LED to flash. When it is
flashing you can adjust to the desired temperature setting. If you hold these buttons down, the
values will rapidly increase or decrease. The new and desired temperature setting will remain
on the LED display for 3 seconds to confirm the new value.
NOTE: The default temperature is 35°C (95°F).
NOTE: Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
J
Power-Saving Timer LED
This LED flashing means you are setting the heating duration. The light will be on when the
heating function starts to work.
This LED flashing means you are setting the number of hours FROM NOW when the heater will
activate. When the light is on, the Power-Saving Timer function is set.
K
On/Off Button
Press this button for 2 seconds to active the control panel bottons and the light turns to green.
Press this button for 2 seconds to turn off all currently activated functions.
L
LED Display
Once powered up, the LED displays the current water temperature automatically.
After 72 hours of filtration (without using the power saving timer function), the pump will
hibernate and flash "End" with the current water temperature. When the pump is hibernating
both the heating and water filter functions are disabled. To re-active the pump press
lock/unlock button for 3 seconds.
NOTE: The water heat rate may change in the below conditions:
· When the outdoor temperature is below 15°C (59°F).
· If the cover is not in position when the heating function is activated.
NOTE: To display the current water temperature, run the filter system for at least a minute. The water
temperature as tested by an external thermometer may vary from the temperature as displayed on the spa
panel due to the differing positions of the measurement devices.
1. Unplug the pump, strike the side of the pump firmly (but not violently), and plug
it back in.
2. Contact your local Bestway Aftersales Service Center for instructions.
1. Remove the two stopper caps before starting the heating system. Refer to the
Assembly section in the User's Manual.
2. Remove the filter set from inside the pool and push the filter or heat button. If no
alarm appears, clean or change the filter cartridges and re-install the filter set
inside the pool.
3. Contact your local Bestway Aftersales Service Center for instructions.
appears, the
1. The spa is not designed to operate with water temperatures lower than 4ºC (40°F).
Unplug the pump and only re-start the pump when the water temperature reaches
6°C (43°F).
2. Contact your local Bestway Aftersales Service Center for instructions.
1. The spa is not designed to operate with water temperatures greater than
40°C (104°F). Unplug the pump and only re-start the pump when the water
temperature reaches 38°C (100°F) or lower.
IMPORTANT: Before you're-start the pump, push the pump's reset button.
2. Contact your local Bestway Aftersales Service Center for instructions.
Contact your local Bestway Aftersales Service Center for instructions.
1. Unplug the pump and push the reset button, then plug the pump back in.
2. In case the alarm still remains, check the RESET BUTTON section in manual.
3. Contact your local Bestway Aftersales Service Center for instructions.
Contact your local Bestway Aftersales Service Center for instructions.
1. Follow the instructions in operation part to remove the salt.
2. Contact your local Bestway Aftersales Service Center for instructions.
1. Follow the instructions in operation part to add salt in the water.
2. Contact your local Bestway Aftersales Service Center for instructions.
Contact your local Bestway Aftersales Service Center for instructions.
Contact your local Bestway Aftersales Service Center for instructions.
11
HYDROJET
Solutions
S-S-004815

Advertisement

loading

This manual is also suitable for:

Lay-z-spa 54144