5.3 - ERRORS

In case of a problem, the device shuts down and the display will show one error message from the following
Message
Description
Battery power
E1
(The battery-saver has activated. Power decreased below the
set threshold.)
Power overload from the cooling fan
E2
(The cooling fan overloads the board beyond the allowed
limit. Possible cause: short circuit or something is blocking the
fan from rotating.)
Blocked compressor
E3
(The rotor is blocked or the pressure in the cooling circuit is
too high.)
E4
Overcurrent on the compressor
High temperature in the control board
E5
(If the cooling circuit is overloaded or if the surrounding
temperature is too high, the control board signals this issue.)
Empty circuit
E6
(The system may have lost gas.)
Temperature probe
E7
(If the probe has short circuited or has become disconnected,
the device stops working.)
Power overload from the condenser fan
E9
(The cooling fan overloads the board beyond the allowed
limit. Possible cause: short circuit or something is blocking the
fan from rotating.)
Disconnected compressor
E0
A power supply cable of the compressor has disconnected.
IT
IT
EN FR DE ES
EN FR DE ES
Troubleshooting
Start the vehicle in order to recharge the battery.
Take the device to an authorised
The presence of
malfunction, but is a normal management procedure for the
compressor by the electronic board. Only if the code continues to
be displayed contact an authorized dealer.
Take the device to an authorized
list.
dealer.
E3
E4
E5
codes do not indicate a
dealer.
23