Thank you for choosing an ECO Spot™ 2500 Profile Spot. The
projector part is based on a modified ETC Source Four® and
most of the available standard Source Four equipment, such as
rotators, changers, etc. can be utilized. 575W Discharge lamp
technology paired with an ultra-efficient optical system makes
it brighter, more versatile and compact than any classic 2500W
gobo projector. Please read this manual before installing or
operating it. Follow the safety precautions listed below and observe all warnings.
This document covers the special functionality of the ES-2500, for general/detailed
info on other functions, please refer to the ETC Source Four User manual.
DO NOT OPERATE THE LAMP HEAD WITH THE LAMP EXPOSED. EVEN SHORT AND
INDIRECT EXPOSURE CAN CAUSE SERIOUS EYE AND SKIN INJURY.
Package Contents
Projector housing based on a modified Source Four fixture.
Electronic ballast system with lamp head and power cord.
Optional accessories depending on product configuration
Safety Information
FOR PROFESSIONAL USE ONLY
NEVER OPERATE THE UNIT WITH THE LIGHT BULB EXPOSED; IT CAN CAUSE
BLINDNESS OR SERIOUS EYE INJURY.
ONLY OPERATE THE FIXTURE FULLY ASSEMBLED
MAKE SURE THE FIXTURE IS UNPLUGGED BEFORE CHANGING THE LAMP
Do not look directly into the lamp, it may result in eye damage.
This product is for not for household use, it presents risks of severe injury or death
due to fire and burn hazards, electric shock, lamp explosion and falls.
This fixture should be installed and operated only by qualified personnel with
experience in lighting equipment and general electrical experience.
Always disconnect the unit from power and allow cooling down for 20 minutes
before servicing.
Minimum distance to flammable materials = 6 ft. (2 m).
Minimum distance to illuminated surfaces = 9 ft. (3 m).
Don't touch the hot surface during operation, use gloves if necessary.
Always ground (earth) the fixture electrically.
Copyright © 2012 Globus New Media LLC
ECO Spot 2500 User Manual
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECO Spot 2500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Globus New Media ECO Spot 2500

  • Page 1  Minimum distance to illuminated surfaces = 9 ft. (3 m).  Don’t touch the hot surface during operation, use gloves if necessary.  Always ground (earth) the fixture electrically.  Copyright © 2012 Globus New Media LLC Page 1...
  • Page 2: Warranty

    Focus the light by moving the lens barrel back and forth.  Follow the standard ETC Source Four Operating Manual for regular procedures.  Adjust the lamp position if necessary, see “Lamp Adjustment”.  Page 2 Copyright © 2012 Globus New Media LLC...
  • Page 3 Discharge bulbs should be replaced before the end of their specified bulb life. The  integrated hour counter is used as reference to determine the time that the bulb has been in use. It cannot be reset. Copyright © 2012 Globus New Media LLC Page 3...
  • Page 4 Check- and adjust if necessary for an even field as described in “Lamp Adjustment”.  Gobo Placement / Focusing / General Use See “Gobo Types and Dimensions” below.  Please refer to the ETC Source Four User Manual for general instructions.  Page 4 Copyright © 2012 Globus New Media LLC...
  • Page 5 Find a position where the dark spot just becomes an evenly bright center The  smaller the contrast between center and rest of the field, the better. An extremely bright center (hot spot) can damage the gobo due to overheating. Copyright © 2012 Globus New Media LLC Page 5...
  • Page 6 Turn all Screws CCW Turn all Screws CW       Light Right Adjusted Turn B CW, correct vertically with A CW The center is slightly light, which is ok       Page 6 Copyright © 2012 Globus New Media LLC...
  • Page 7 Check- and adjust if necessary for an even field as described in “Lamp Adjustment”.  Gobo Placement / Focusing / General Use See “Gobo Types and Dimensions” below.  Please refer to the ETC Source Four User Manual for general instructions.  Copyright © 2012 Globus New Media LLC Page 7...
  • Page 8 Average Bulb Life: 1,000h Color temperature: 6,000 K Color temperature: 6,000 K Color Rendering Index CRI: 75 Color Rendering Index CRI: 85 Luminous Flux 43,000lm Luminous Flux 49,000lm Base: GY9.5: GY9.5 Base: GY9.5 Page 8 Copyright © 2012 Globus New Media LLC...
  • Page 9 No warranty for breakage due to poorly adjusted field (hot spots). See “Lamp Adjustment”. Fits B-size gobos Outer Diameter (OD): 86mm Max. Image Diameter (ID): 66mm (for glass gobos we recommend max 60mm) Max Thickness: 2.7mm in Gobo slot, 4mm in Iris Slot Copyright © 2012 Globus New Media LLC Page 9...
  • Page 10 Fixed Lenses: 5, 10, 14, 19, 26, 36, 50, 70, 90°  Zoom Lenses: 15-30° and 25-50°  All rights reserved, Globus New Media is not liable for errors or omissions. Page 10 Copyright © 2012 Globus New Media LLC...
  • Page 11 ECO Spot 2500 User Manual DMX Module (Optional) The ES-2500 can be equipped with an optional DMX module for control of: Lamp On/Off  Lamp Brightness (100% or 50%)  Copyright © 2012 Globus New Media LLC Page 11...
  • Page 12 ECO Spot 2500 User Manual Photometrics Page 12 Copyright © 2012 Globus New Media LLC...