Using The Battery Monitor - Dometic CFF Series Operating Manual

Compressor fridge/freezer
Hide thumbs Also See for CFF Series:
Table of Contents

Advertisement

Operation
When switching between the AC power supply and the battery supply, the red LED
may light up briefly.
➤ Plug the AC connection cable (fig. 1 3, page 7) into the AC voltage socket of
the cooler (fig. 4 1,page 11).
➤ Connect the connection cable to an AC power outlet.
6.4

Using the battery monitor

The device is equipped with a multi-level battery monitor that protects your vehicle
battery against excessive discharging when the device is connected to the on-board
DC supply.
If the cooler is operated when the vehicle ignition is switched off, the cooler switches
off automatically as soon as the supply voltage falls below a set level. The cooler will
switch back on once the battery has been recharged to the restart voltage level.
A
NOTICE!
DAMAGE HAZARD!
Failure to obey this instruction may result in damage to the battery.
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid starting repeatedly or operating current consumers
without longer charging phases. Ensure that the battery is recharged.
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW" and
"MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restart-voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
The battery monitor mode can be selected as follows:
➤ Switch on the cooler.
➤ Press the "SET" button (fig. 3 5, page 10) three times.
➤ Use the "UP +" (fig. 3 7, page 10) or "DOWN –" (fig. 3 6, page 10) buttons to
select the battery monitor mode.
16
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
CFF35, CFF45
HIGH
11.8 V
12.6 V
24.6 V
26.2 V