Vitea Care Bubble Master User Manual

Vitea Care Bubble Master User Manual

Anti-bedsore alternating pressure bubble mattress

Advertisement

Quick Links

Use'r manual
Edition MG 10.2015
Bubble Master
Anti-bedsore alternating pressure
bubble mattress
VCM202G
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bubble Master and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vitea Care Bubble Master

  • Page 1 Use’r manual Edition MG 10.2015 Bubble Master Anti-bedsore alternating pressure bubble mattress VCM202G...
  • Page 2: Table Of Contents

    Table of Contents Introduction ............................. 3 Description of product ........................3 Contrandications ..........................4 Use ..............................4 Safety of use ............................ 7 Everyday use and maintenance ....................... 7 Technical parametres ........................9 Symbols ............................9 Contact details ........................... 10 PLEASE READ CAREFULLY BEFORE USING WHOLE OF INSTRUCTIONS...
  • Page 3: Introduction

    Introduction Alternating pressure anti-bedsore bubble mattress is equipped with end flaps which allows to place the mattress on the bed. Made of PVC, which is a important to keep it clean. Manual adjustment of the pressure in the mattress gives the possibility of individual adjustment to the patient's weight with a weight up till 140 kg.
  • Page 4: Contrandications

    Illustration 4. Mattress Illustration 5. Mattress cord Prevention and support of bedsore treatment. Due to its tubular structure, the mattress ensures an appropriate arrangement of body weight and correct ventilation (oxygenation and moisture diversion). The air insulation provides an optimal temperature and comfort of use. All of the above-mentioned factors play crucial role for bedsore prophylaxis and treatment.
  • Page 5 The mattress tabs Illustration 6. Connect tube into the mattress and then to the pump via a connecting part. To do this, press indicated in illustration 7 for a place to disconnect the connecting element into the position shown in Illustration 8. Illustration 7.
  • Page 6 Illustration 11. Illustration 12. Plug the power cord into a power outlet. Make sure that the mattress tubes are not bent or twisted. Start the pump by using green button. Position 1 (on) - the pump is switched on. Position 0 (off) - pump is switched off.
  • Page 7: Safety Of Use

    Safety of use WARNING! a) Before using the mattress, refer to this manual and keep it for future reference. b) Permitted user weight 140 kg. c) Please remember that on the mattress should stay only the patient (other people on the mattress are not allowed).
  • Page 8 SHORT-TERM CLOSURE OF THE AIR SUPPLY In a situation when it is necessary to transport a patient with a bed for a short distance very quickly, you can disconnect the mattress from the pump and close the air outlet. To do this, switch off the pump, unplug the power cord from the wall outlet. Remove the connecting element from pump jack and close the air outlet.
  • Page 9: Technical Parametres

    TECHNICAL REVIEW Frequency Object of control Comments Before first Checking the technical condition and Check if any elements have any installation all the elements within the visible mechanical damage. packaging. Once a month Cleanliness and general condition. In case of mechanical damage contact the producer immediately.
  • Page 10: Contact Details

    Read the user's manual Use inside buildings Warning The product is intended to transport by car Catalog number The product is intended to the transport by plane Serial number The product is compliant with standards on electrical and electronic equipment. It should not be disposed with other waste from households.