Samsung RT53 Service Manual page 49

Hide thumbs Also See for RT53:
Table of Contents

Advertisement

1
0
304 views
Total Ver.02
Uploaded by
epalarcon9
Full description
ninguno
Save
Embed
Share
Print
TROUBLESHOOTING
4-2-3. When Defrost does not work (F DEF Heater)
- When there is a trouble in defrosting, select the Self-Diagnosis function before turning off the unit. And,
check if there is any defect in the Defrost Heater. If not, plug out the unit and do the Trouble-Shooting. (Re
to the Self-Diagnosis function and check the details)
** Heater Resistance Reading Location **
F-DEF : Resistance between CN70 #5 (BRN)
CN77 #3 (ORG) should be ohm ± 10%.
** 0Ω : Short / ∞Ω : Open
(Bimetal / Thermal Fuse / Heater Defect)
** Sensor Resi s tance Readi n g Locati o n **
F-DEF : Between CN30 #4 (RED)
** 0Ω : Short / ∞Ω : Open
Temp vs. Resistance Table
30
4.22
20
6.05
10
8.87
0
13.29
-10
20.42
-20
32.23
-30
52.41
** Sensor Voltage Reading Location **
F-DEF : Between PCB COMMON Ground
and CN30 #4 (or SEN_2)
** 0V : Short / 5V : Open
After pressing the Power Cool and
the Fridge buttons simultaneously for
6 seconds, push the Fridge button to
enter the Test Mode.
And then, when any one of t he buttons
is pressed twice, the Forced Defrost will
start and "3 ℃ , 5 ℃  and 7 ℃ " LEDs will
light up on the display panel.
Check the related sensors
if they are defective.
Note
When the temperature of the F DEF Sensor
goes over 12
 with the Defrost Heater heating up, it
stops heating and it goes back to Cooling Operation.
SEG
Voltage
230
RT29/
RT32
120
230
RT35/
Hotpoint,Mba
4033 Cv
 CN76-"1" (GRY)
For more
detail data,
refer to
DATA1. Temp
Table
No
After heating up for a while, it
goes back to Cooling Operation
Watt
OHM
130
406.9
130
110.8
160
330 6
RELATED TITLES
LG_MULTI_F_3828A20097W_1[1]
Start
No
All Defrost Heaters
are normal?
Yes
Defrost Sensor is
No
normal? (Check it
with Self-Diagnosis)
Yes
The Sensor
No
Temperature Value
is lower than 12 ℃ .
Yes
Do Forced Defrost
Power is applied to
F-Defrost Heater.
No
Yes
Yes
Normal
MAIN PCB
No
Connection is normal?
Samsung
34648123
Refrigerador
WD856UH
☞ When checking wit
F DEF. ERROR
the Self Diagnosis
Check Bimetal, Heater
Continuity or Wire Connection
Replace the Sensor
Forced Operation for a while