Download Print this page

Clas Ohlson 3001 A Manual

Torque wrench

Advertisement

Available languages
  • EN

Available languages

Quick Links

Torque Wrench
Art.no. 30-6309 Model 3001 A
Please read the entire instruction manual before use and save it for future reference. We reserve
the right for any errors in text or images and for making any necessary technical changes to this
document. If you should have any questions concerning technical problems please contact our
Customer Services.
Caution
Never use the torque wrench to undo nuts, bolts or other fasteners as this will damage the ratchet
mechanism and the calibrated settings.
Setting the torque
Fig. 1
Handle
Conversion chart
To
From
mNm
cNm
Nm
daNm
millinew-
centinew-
newton-
decanew-
tonmeter
tonmeter
meter
tonmeter
mNm
1
0.1
0.001
0.0001
cNm
10
1
0.01
0.001
Nm
1,000
100
1
0.1
daNm
10,000
1,000
10
1
cmkg
98
9.8
0.098
0.0098
mkg
9,810
981
9.81
0.98
in-oz
7.05
0.705
0.00705
0.000705
in-lb
112.8
11.28
0.1128
0.01128
ft-lb
1,350
135
1.35
0.135
GREAT BRITAIN • customer service tel: 08545 300 9799 e-mail: customerservice@clasohlson.co.uk internet: www.clasohlson.com/uk
Locking screw.
Clockwise to lock.
Anticlockwise
to unlock.
cmkg
mkg
in-oz
in-lb
ft-lb
centi-
meter
inches-
inches-
foot-pounds
meter kg
kg
ounces
pounds
0.0102
0.000102
0.1418
0.00886
0.000738
0.102
0.00102
1.418
0.0886
0.00738
10.2
0.102
141.8
8.863
0.738
102
1.02
1418
88.63
7.38
1
0.01
13.9
0.869
0.0724
100
1
1390
86.90
7.24
0.072
0.00072
1
0.063
0.0052
1.152
0.0115
16
1
0.083
13.8
0.138
192
2
1
Example settings for model 3001 A,
Example 1
Setting the torque wrench to 96 Nm:
1. Undo the handle locking screw. See fig. 1.
2. Set the handle to 90 Nm. See fig. 2.
3. 1 gradation on the handle = 1 Nm.
6 gradations = 6 Nm.
90 + 6 = 96 Nm. See fig. 3.
4. Lock the handle. See fig. 1.
Example 2
Setting the torque wrench to 70.84 foot-pounds (ft-lb).
1. Undo the handle locking screw. See fig. 1.
2. Set to 66.4. See fig. 4.
3. 1 gradation on the handle = 0.74 ft-lb.
6 gradations = 4.44 ft-lb.
66.4 + 4.44 = 70.84 ft-lb. See fig. 5.
4. Lock the handle. See fig. 1.
Use
Important:
1. Always the use the correct size socket and, if applicable, accessory.
2. Apply a steady pull to the handle. When the set torque has been reached it will be indicated
as follows:
a. An audible click. The click will be quieter at lower torque settings.
b. The tension on the handle will break.
c. The handle will visibly break at the set torque.
Warning:
1. Never continue pulling after the set torque has been reached. This will result in an incorrect
torque being applied and could damage parts.
2. If the torque wrench has not been used for a long time or has been in storage, use it at a low torque
setting pulling the handle several times to allow the internal components to re-lubricate themselves.
3. Set the torque wrench to the lowest setting when it is not to be used for some time.
4. Do not adjust the handle lower than the lowest torque setting.
5. Never use the torque wrench to undo nuts, bolts or other fasteners. This could damage the
ratchet mechanism.
6. The torque wrench is robust and designed for workshop use. However, it is also a precision
measuring instrument and should be treated as such.
7. Clean the wrench by wiping it with a cloth now and then. Do not immerse the wrench in any
kind of cleaning agent. This will affect the internal lubrication.
Always refer to the manufacturer's recommended torque settings and sequences for tightening.
½
" square drive
Fig. 3
Fig. 2
Fig. 5
Fig. 4

Advertisement

loading

Summary of Contents for Clas Ohlson 3001 A

  • Page 1 Torque Wrench ½ ″ square drive Example settings for model 3001 A, Example 1 Art.no. 30-6309 Model 3001 A Setting the torque wrench to 96 Nm: 1. Undo the handle locking screw. See fig. 1. Please read the entire instruction manual before use and save it for future reference. We reserve 2.
  • Page 2 Momentnyckel ½ ″ fyrkant-fäste Exempel på inställning med modell 3001 A, Exempel 1 Art.nr 30-6309 Modell 3001 A Momentnyckeln skall ställas in på 96 Nm: 1. Lossa handtagets låsskruv. Se fig. 1. Läs igenom hela bruksanvisningen före användning och spara den sedan för framtida bruk.
  • Page 3 Momentnøkkel Eksempel på innstilling med modell 3001 A, ½″ firkantfeste Eksempel 1 Art.nr. 30-6309 Modell 3001 A Momentnøkkelen skal stilles inn på 96 Nm: 1. Løsne på håndtakets låseskrue. Se fig. 1. Les nøye igjennom hele bruksanvisningen og ta vare på den til senere bruk. Vi reserverer oss 2.
  • Page 4: Vääntömomentin Säätö

    Momenttiavain ½ ″ nelikantakiinnitys Säätöesimerkki: malli 3001 A, Esimerkki 1 Tuotenro 30-6309 Malli 3001 A Momenttiavaimen momentiksi säädetään 96 Nm: 1. Irrota kahvan lukitusruuvi. Katso kuva 1. Lue käyttöohjeet ennen tuotteen käyttöönottoa. Säilytä käyttöohjeet tulevaa tarvetta varten. 2. Säädä 90 Nm. Katso kuva 2.
  • Page 5: Bedienung

    Drehmomentschlüssel Beispiele für die Einstellung mit Modell 3001 A, ½″ Einsteck-Vierkant Beispiel 1 Art.Nr. 30-6309 Modell 3001 A Der Drehmomentschlüssel soll auf 96 Nm eingestellt werden. 1. Die Konterschraube am Griff lösen. Siehe Abb. 1. Vor Anwendung die Bedienungsanleitung vollständig durchlesen und für künftigen Gebrauch 2.

This manual is also suitable for: