Helios KWL-CO2 eC Installation And Operating Instructions Manual

Helios KWL-CO2 eC Installation And Operating Instructions Manual

Room sensor for measuring the co2 concentration in room air
Hide thumbs Also See for KWL-CO2 eC:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D'UTILISATION
Raumsensor zur Erfassung der CO
der Raumluft
Room sensor for measuring the CO
room air
Sonde d'ambiance pour détecter la concentration de
CO
dans l'air ambiant
2
KWL-CO2 eC
-Konzentration in
2
concentration in
2
DE
EN
FR

Advertisement

Table of Contents
loading

Summary of Contents for Helios KWL-CO2 eC

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS NOTICE DE MONTAGE ET D’UTILISATION Raumsensor zur Erfassung der CO -Konzentration in der Raumluft Room sensor for measuring the CO concentration in room air Sonde d‘ambiance pour détecter la concentration de dans l‘air ambiant KWL-CO2 eC...
  • Page 2: Allgemeine Hinweise

    Produkt den zum Zeit punkt seiner Herstellung gültigen Vorschriften und EG-Richtlinien. 1.5 Sendungsannahme Die Lieferung enthält den Raumsensor KWL-CO2 eC. Die Sendung ist sofort bei Anliefe- rung auf Beschädigungen und Typenrichtigkeit zu prüfen. Falls Schäden vorliegen umge- hend Schadensmeldung unter Hinzuziehung des Transportunternehmens veranlassen.
  • Page 3 EN 61 326, EMV-Richtlinie 2014 ⁄ 30 ⁄ EU, Niederspannungsrichtlinie 2014 ⁄ 35 ⁄ EU Die empfohlene Montagehöhe des Raumsensors KWL-CO2 eC liegt zwischen 1,4 bis HINWEIS 1,5 m, bei dieser Höhe werden üblicherweise stehende und sitzende Personen gleich- mäßig berücksichtigt.
  • Page 4: Elektrischer Anschluss

    RFTM - LQ - CO - Modbus AERASGARD ®  Montage- und Betriebsvorschrift Raumsensor KWL-CO2 eC Maßzeichnung R CO - Modbus Dimensional drawing RLQ - CO - Modbus 2.2 Maße Plan coté RFTM - CO - Modbus Габаритный чертеж RFTM - LQ - CO - Modbus Abb.
  • Page 5 1 2 3 4 5 6 7 8 Ihres Gerätes V+ GND zero of fset Insgesamt maximal 6 KWL-CO2 eC + KWL-VOC eC möglich. Bitte Anschlussplan ss_1433 beachten. Modbus Adressbereich CO2 / VOC Jede Adresse darf nur einmal 70 - 75...
  • Page 6 – Anschluss gemäß Schaltplan SS-1404. Bei Anschluss an ein Gerät, dessen An- schlussplan beachten, siehe Montage und Betriebsvorschrift. Adressierung Sind mehrere Raumsensoren KWL-CO2 eC angeschlossen, muss die Adressierung angepasst werden. Es darf keine Doppelvergabe der Adressen für die Fühler erfol- gen! (s. Dip-Schalter Tabelle; Schaltplan SS-1404).
  • Page 7 Montage- und Betriebsvorschrift Raumsensor KWL-CO2 eC...
  • Page 8: General Information

    Our warranty shall not apply if the following instructions are not observed. The same applies for liability claims against the manufacturer. The use of accessories, which are not recommended or offered by Helios, is not permitted. Any damage that may occur is not liable for warranty.
  • Page 9 1.4 and 1.5 m, persons who are usually standing and sitting are considered equally at this height. The room sensor KWL-CO2 eC can also be installed at a different height if the specific spatial conditions do not allow the recommended installation height.
  • Page 10: Electrical Connection

    RFTM - LQ - CO - Modbus ®  AERASGARD Installation and operating instructions Room sensor KWL-CO2 eC Maßzeichnung R CO - Modbus Dimensional drawing RLQ - CO - Modbus 2.2 Dimensions Plan coté RFTM - CO - Modbus Габаритный чертеж...
  • Page 11 V+ GND zero of fset Maximum total of 6 KWL-CO2 eC + KWL-VOC eC possible. Please observe w iring diagram ss_1433. Modbus address range CO2 / VOC Each address may only be used once 70 - 75...
  • Page 12: Operation

    – Connection according to wiring diagram SS-1404. When connecting to a unit, observe its wiring diagram, see the Installation and Operating Instructions. Addressing If multiple room sensors KWL-CO2 eC are connected, the addressing must be adjusted. There must be no double address allocations for sensors! (see DIP switch table; wiring diagram SS-1404).
  • Page 13 Installation and operating instructions Room sensor KWL-CO2 eC...
  • Page 14: Notes Généra- Les

    Toute demande de remplacement ou de réparation à titre gratuit sera déclinée en cas de non-respect des indications contenues dans la notice. L’utilisation d’accessoires, non fournis, non conseillés ou non proposés par Helios, est interdite. Si ces consignes ne sont pas respectées, la garantie s’annule. Idem pour les réserves constructeur.
  • Page 15 1,4 et 1,5 m. À cette hauteur, les personnes debout et assises sont généralement prises en compte de manière uniforme. La sonde d‘ambiance KWL-CO2 eC peut également être montée à une hauteur diffé- rente si les conditions spécifiques du local ne permettent pas la hauteur de montage...
  • Page 16: Raccordement Électrique

    RFTM - LQ - CO - Modbus ®  AERASGARD Notice de montage et d‘utilisation Sonde d‘ambiance KWL-CO2 eC Maßzeichnung R CO - Modbus Dimensional drawing RLQ - CO - Modbus 2.2 Dimensions Plan coté RFTM - CO - Modbus Габаритный чертеж...
  • Page 17 V+ GND of fset zero Un total de maximum 6 KWL-CO2 eC + KWL-VOC eC possible. Veuillez observer le schéma de connexion ss_1433. Gamme d'adresses Modbus CO2 / VOC Chaque adresse ne peut être utilisée 70 - 75 qu'une seule fois Réglage par défaut :...
  • Page 18 Adressage Si plusieurs sondes d‘ambiance KWL-CO2 eC sont raccordées, l‘adressage doit être adapté. Les adresses des sondes ne doivent pas être attribuées deux fois ! (voir le tableau des interrupteurs DIP ; schéma de câblage SS-1404)
  • Page 19 Notice de montage et d‘utilisation Sonde d‘ambiance KWL-CO2 eC...
  • Page 20 Service und Information HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen F HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen 93155 Le Blanc Mesnil Cedex HELIOS Ventilatoren ·...

Table of Contents