Summary of Contents for Hioki 9636-01

  • Page 1 INSTRUCTION MANUAL For...は専用機種。複数の場合は「/」で区切る。 不要の場合はとる。 形名を入力。 複数の場合は「/」で区切る。 9636-01 品名を入力。 RS-232C PACKAGE...
  • Page 3: Table Of Contents

    Contents Introduction Shipping Check Safety Precautions for Using the RS-232C PACKAGE Chapter 1 RS-232C PACKAGE Overview 1 Chapter 2 Specifications 2.1 General Specifications 2.2 RS-232C PACKAGE Function Specifications 2.3 Screen Example Chapter 3 Connection Procedure Chapter 4 Program Installation Chapter 5 3286 (-20) Settings 5.1 OPTION Mode 5.2 DATA OUTPUT SETUP Mode 5.3 Default Settings...
  • Page 5: Shipping Check I

    If perchance you find any unclear portions, mistakes, omissions, or the like, we would be most obliged if you could please notify us of them via any HIOKI agent, or directly. Shipping Check When the product is delivered, check and make sure that it has not been damaged in transit.
  • Page 6: Safety

    ――――――――――――――――――――――――――― Safety DANGER Incorrect measurement procedures could result in injury or death, as well as damage to the equipment. Please read this manual carefully and be sure that you understand its contents before using the equipment. The manufacturer disclaims all responsibility for any accident or injury except that resulting due to defect in its product.
  • Page 7 ――――――――――――――――――――――――――― The following symbols are used in this Instruction Manual to indicate the relative importance of cautions and warnings. Indicates that incorrect operation presents possibility of injury to the user CAUTION or damage to the equipment. Denotes items of advice related to performance of the equipment or to its NOTE correct operation.
  • Page 8: Precautions For Using

    40 . Please be aware of the following items before use: The "RS-232C PACKAGE" is copyrighted by HIOKI E.E. Corporation. Reproducing, copying or modifying the product in whole or in part, except for the specific purpose of processing data for the 3286 (-20), is prohibited by law.
  • Page 9 Never use abrasives orsolvent cleaners. Hioki shall not be held liable for any problems with a computer system that arises from the use of this CD, or for any problem related to the purchase of a Hioki product.
  • Page 10: Chapter 1 Rs-232C Package Overview

    ――――――――――――――――――――――――――― Chapter 1 RS-232C PACKAGE Overview The "RS-232C PACKAGE" is a PC software program that processes data from the HIOKI Model 3286 (-20) CLAMP ON POWER HiTESTER. ―――――――――――――――――――――――― Chapter 1 RS-232C PACKAGE Overview...
  • Page 11: Chapter 2 Specifications

    ――――――――――――――――――――――――――― Chapter 2 Specifications 2.1 General Specifications Media: One CD (Exclusive PC application software) Compatible Measuring Instrument: HIOKI Model 3286 (-20) CLAMP ON POWER HiTESTER Operating Environment (Note 1) Microsoft Windows 95 Microsoft Windows 2000 Microsoft Windows Me Microsoft Windows NT 4.0 Note 1: Microsoft Windows 95 must be OSR2 or later version.
  • Page 12: Rs-232C Package

    ――――――――――――――――――――――――――― 2.2 RS-232C PACKAGE Function Specifications Maximum readings 32700 accepted File operations Open file and save file Printing Data printing Recording CSV format Communications Acquires data via RS-232C ―――――――――――――――――――――――― Chapter 2 Specifications...
  • Page 13: Screen Example

    ――――――――――――――――――――――――――― 2.3 Screen Example The screen of 3φPF Meter The screen of harmonics ―――――――――――――――――――――――― Chapter 2 Specifications...
  • Page 14 ――――――――――――――――――――――――――― 1. Function Mode Indication This area shows the measurement function and mode. 1P_P 1φP Meter 1P_PF 1φPF Meter 3P_PF 3φPF Meter HARM_I Current harmonics HARM_U Voltage harmonics 2. Range Indication This area shows the current and voltage ranges. When auto-ranging is enabled, the auto-selected range is indicated within parenthesis, as in "AUTO (600V)"...
  • Page 15: Chapter 3 Connection Procedure

    ――――――――――――――――――――――――――― Chapter 3 Connection Procedure Use the supplied cable to connect the 3286 (-20) to the PC. RS-232C connector PC Connection Be careful of the cable direction when connecting it NOTE to the 3286 (-20). ―――――――――――――――――――――――― Chapter 3 Connection Procedure...
  • Page 16: Chapter 4 Program Installation

    ――――――――――――――――――――――――――― Chapter 4 Program Installation 1. Confirm that the operating environment satisfies the requirements in "Chapter 2. Specifications" above, and insert the RS-232C PACKAGE diskette into the CD-ROM drive. 2. Open My Computer, and select the CD-ROM drive with the RS-232C PACKAGE diskette. 3.
  • Page 17: Chapter 5 3286 (-20) Settings

    OPTION mode. 1. OPTION Types Input Model Name Function type RS-232C 9636-01 9636-01 PC Output PACKAGE 2. To activate the OPTION mode, hold the while pressing to turn the 3286 (-20) on. POWER 3. The digit selected for changing the OPTION mode blinks.
  • Page 18: Data Output Setup Mode

    ――――――――――――――――――――――――――― is displayed, then turn the power off. is displayed, and the option setting reverts to its default. The digits may not flash, depending on the version NOTE of software used for the 3286 (-20). When using a version of software for which the digits do not flash, use the key to change the input type setting.
  • Page 19 ――――――――――――――――――――――――――― 4. If needed, the settings can be returned to their default values by pressing the key twice. HOLD 5. When finished setting, turn the power off: (SAVE END) is displayed as the settings are saved. Display 2 Display 1 Display 3 Default Item...
  • Page 20: Default Settings

    ――――――――――――――――――――――――――― (4) RS-232C Communications Speed: Item 2-04 (BAUD) Select from 2400/4800 or 9600 bps (5) RS-232C Data Length: Item 2-05 8 bits Set data length to 8 bits 7 bits Set data length to 7 bits (6) RS-232C Stop Bits: Item 2-06 1 bit Select one stop bit 2 bits...
  • Page 21: Data Format

    ――――――――――――――――――――――――――― Holding down the key, as turning power RANGE NOTE on, will display " " and initialize all the saved settings (RS-232C settings, SETUP function and measurement status saving function). 5.4 Data Format The 3286 (-20) outputs measurement data at each interval of about six seconds.
  • Page 22 ――――――――――――――――――――――――――― Data Power Harmonic measurement number measurement Ipeak or U or U or U or U or U COSφ or U SINφ or U φ or U LEAD/LAG or U or U Phase detection Battery capacity I or U or U or U or U or U...
  • Page 23 ――――――――――――――――――――――――――― Data Power Harmonic measurement number measurement or U harmonic percentage or U harmonic percentage or U harmonic percentage or U harmonic percentage Display order Battery capacity Line Line Number 1φP Meter 1φPF Meter 3φPF Meter Current hermonics Voltage hermonics ――――――――――――――――――――――――...
  • Page 24 ――――――――――――――――――――――――――― Display data LCD display (DSIP1,DISP2,DISP3) Number P,U,I S,U,I I,Ipeak,IHz U,Upeak,UHz P,-,Q S,-,Q COSφ,U,I φ,U,I SINφ,U,I P instantaneous value,P maximum value,P minimum value S instantaneous value,S maximum value,S minimum value I instantaneous value,I maximum value,I minimum value Ipeak instantaneous value,Ipeak maximum value,Ipeak minimum value U instantaneous value,U maximum value,U minimum value...
  • Page 25 ――――――――――――――――――――――――――― Range Current range 200A 1000A 20A AUTO Voltage range 150V 300V 600V AUTO Phase Detection Phase detection Number Missing phase Normal phase Reverse phase None LEAD/LAG LEAD/LAG Number LEAD None Format of easurement values Format of easurement values Normal Mantissa: Max 4-digit numerial value + decimal point Exponent: 1-digit numerial value...
  • Page 26 ――――――――――――――――――――――――――― Output example [1φP Meter] Line Display data Voltage range Current range +106.4E+0 +151.8E+0 Upeak +055.0E+0 +098.8E+0 +145.6E+0 Ipeak +055.0E+0 +03.55E+3 +10.51E+3 +09.90E+3 +0.338E+0 COSφ +0.941E+0 SINφ φ +070.3E+0 LEAD/LAG Phase detection Battery capacity [Harmonic measurement] Line Display data Range +002.6E+0 THD-R +002.6E+0...
  • Page 27 ――――――――――――――――――――――――――― +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.1E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +000.0E+0 +100.0E+0 harmonic percentage +002.4E+0 harmonic percentage harmonic percentage +000.9E+0 +000.1E+0 harmonic percentage +000.0E+0 harmonic percentage harmonic percentage +000.1E+0 +000.1E+0 harmonic percentage +000.0E+0 harmonic percentage harmonic percentage +000.0E+0 +000.0E+0 harmonic percentage...
  • Page 28: Chapter 6 Troubleshooting

    ――――――――――――――――――――――――――― Chapter 6 Troubleshooting Although the following problems might seem to be program malfunctions, they can result from other causes. So before seeking repair service, please confirm the indicated items. Symptom Confirmation item Not able to display it Confirm that the RS-232C cable is properly connected to the 3286 (-20).
  • Page 29 ――――――――――――――――――――――――――― Check the following setup when the connection is not established. Setup example Baud Data Stop Port Parity Rate Length 3286 (-20) 9800 8bit 1bit None Settings lm3286.exe Set up COM1 9800 8bit 1bit None Com Port Lower both Band Rates when RS-232C indication goes on and off.
  • Page 30 ――――――――――――――――――――――――――― ―――――――――――――――――――――――― Chapter 6 Troubleshooting...
  • Page 31 HIOKI 9636-01 RS-232C PACKAGE Instruction Manual Publication date: December 2007 Revised edition 2 Edited and published by HIOKI E.E. CORPORATION Technical Support Section All inquiries to International Sales and Marketing Department 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL: +81-268-28-0562 / FAX: +81-268-28-0568 E-mail: os-com@hioki.co.jp...
  • Page 32 HEAD OFFICE 81 Koizumi, Ueda, Nagano 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp / URL http://www.hioki.com/ HIOKI USA CORPORATION 6 Corporate Drive, Cranbury, NJ 08512, USA TEL +1-609-409-9109 / FAX +1-609-409-9108 9636B980-02 07-12H Printed on recycled paper...