Available languages

IP camera Instructions
GB
GB
Configuration and Set-up

2.5. Reset to default settings

Disconnect the camera from the power supply
Press and hold the reset key
Continue to hold the reset key and connect
the camera to the power supply
Stop pressing the key when the LED starts
flashing (after approx. 15-30 seconds)
The following settings must be carried out
again after the reset:
For 20-2906A-IP/21-2906A-IP/43-9588/
20-2913A-IP/21-2913A-IP/50-2906A-IP:
1. Allocate camera password
2. Capture mode: 1080P (1920x1080)
3. Powerline frequency: 50 Hz.
4. System/Direct configuration/Network/
Network HTTP: set to Basic
Deactivate "ZeroConf" Enabled
5. Wide dynamic range: off
20-2906A-IP/21-2906A-IP/43-9588/
20-2913A-IP/21-2913A-IP/50-2906A-IP/
43-9582
30
For 43-9582:
1. Allocate camera password
2. Powerline frequency: 50 Hz
3. HTTP/RTSP password settings:
unencrypted only
For 43-9582A /43-9582B:
1. Allocate camera password
2. Powerline frequency: 50 Hz
3. System/Direct configuration/Network/
Network HTTP: set to Basic
Deactivate "ZeroConf" Enabled
!
These settings should only
be carried out if the AXIS
web front end is known
well enough.
43-9582A/43-9582B – Remove the cover
panel from the camera to push the reset
button!