Analog Relay Mux Board
_____ _ ________________________ _
VOPT Connection Of INPUT+ line.
R13, 100k, pulls up to isolated +15volts.
R13, 100k, pulls down to isolated Ground.
R13 Disconnected, No open circuit detect on INPUT+.
______________________ _
AD1200 Register Resume.
The register of the AD1200 card are now quickly listed as
an aide to explaining the sample program.
Figure 1-11. AD1200 Register Map.
______________________________ _
ADDRESS
DEFAULT
OFFSET
ADDRESS
0000 R/W
0218 Hex A/D CONTROL STATUS REGISTER
0001 R/W
0219 Hex A/D GAIN CONTROL REGISTER
0002 R/W
021A Hex A/D, DAC0 LOW BYTE
0003 R/W
021B Hex A/D, DAC0 HIGH BYTE
0004
W
021C Hex DAC1 LOW BYTE
0005
W
021D Hex DAC1 HIGH BYTE
0006 R/W
021E Hex DIGITAL I/O PORT
0007 R/W
021F Hex TIMER CONTROL, EXTENDED MODE TIMERXM TIMERXM
Note: Registers Do Not Always Read Back What Has Been Written
The A/D Control Status Register.
____________________________ _
The most important register in the AD1200 series of cards
is the control status register. It is the primary control register for
the AD Converter, it holds the A/D Busy and A/D Done bits
which indicate whether an A/D conversion is in progress or
_________________________ _
Figure 1-10. VOPT Selection.
REGISTER
Reference
READ
WRITE
ADCSR
ADCSR
ADGCR
ADGCR
DAC0LO ADCLO
DAC0HI ADCHI
DAC1LO
DAC1HI
DIGIN
DIGOUT
Page 13