Application Guide - Vanair ADHD Powertech Installation, Operation, Maintenance And Parts List Manual

125 to 185 cfm rotary screw air compressor
Table of Contents

Advertisement

SPECIFICATIONS
3.3

Application Guide

Water must be drained from the receiver periodically. In high ambient temperature and high
humidity conditions, condensed moisture may emulsify with the oil forming a "milky" color.
The fluid should be changed if this condition develops.
IMPORTANT — DO NOT mix different types of fluids. Combinations of different
fluids may lead to operational problems such as foaming, filter
plugging, orifice or line plugging. Mixing different types of fluids
will void the warranty.