• aircleaner
Operation
Start the sasoo by switching the On/Off switch
. Before
1
commissioning, check that the air inlets and the air outlets of
the unit are free and not covered.
The indicator light
signals the status of the unit, the HEPA
2
fi lter and the CO
content of the room air.
2
The extraction power of the unit can be adjusted freely (any-
where in the range from 0 - 750 m³/h) to the desired applica-
tion requirement using the potentiometer
. At full power,
3
this makes it possible to clean a room with up to 122 m³ with
6 times air exchange per hour.
4
1
3
2
The extraction power can be continuously increased by clock-
wise rotation and continuously reduced by counterclockwise
rotation. Lower extraction power helps reduce energy con-
sumption and noise emissions in smaller rooms.
The unit has a boost mode
Pressing this button increases
4
the blower output to a maximum of 1,400 m³/h. This signifi -
cantly increases the air exchange rate, and the room air is
cleaned faster. Pressing the button again terminates the boost
mode.
28