Advertisement

Quick Links

Operating instructions for the
sasoo aircleaner
Article no.: 2-00211
IMPORTANT:
Read these instructions carefully before using your new aircleaner. Retain the instructions for future use.
Status 02/2021

Advertisement

Table of Contents
loading

Summary of Contents for ULT sasoo 2-00211

  • Page 1 Operating instructions for the sasoo aircleaner Article no.: 2-00211 IMPORTANT: Read these instructions carefully before using your new aircleaner. Retain the instructions for future use. Status 02/2021...
  • Page 3: Table Of Contents

    aircleaner • Contents Introduction General information Intended purpose Safety Symbols Basic safety instructions Obligation of the operating company Obligations of personnel Safety instructions relating to fire hazards Safety instructions for CRM substances Safety at work Residual risks Unit components and technical data Rating plate Technical overview Technical depiction...
  • Page 4 • aircleaner Contents Maintenance and servicing General maintenance and servicing instructions Filter replacement Change HEPA filter Change activated carbon filter Possible malfunctions Replacement filter Service Notices on electronic device disposal Contact Attachment EU declaration of conformity Confirmation of the first electronic test according to DGUV Contents...
  • Page 5: Introduction

    ULT AG shall accept no liability for injuries and damage to persons, animals, machines, the environment and property caused by incorrect installation, repair and maintenance or by improper use.
  • Page 6 • aircleaner The sasoo is suitable for the extraction and filtration of non- explosive and non-flammable air contaminated with aerosols. The cleaned air can be fed back into the working area. Use of the sasoo significantly reduces the concentration of aerosols in interior spaces.
  • Page 7: Safety

    aircleaner • Safety The sasoo is constructed in accordance with state-of-the-art technology and is safe to operate. Nevertheless, hazards may arise from the unit if it is used incorrectly by untrained personnel or not as intended. In the development and production of the sasoo, all steps were taken to ensure that the safety requirements stated in the directives and standards listed in the EU declaration of conformity are complied with.
  • Page 8: Basic Safety Instructions

    • aircleaner Warning: Indicates a medium-risk hazard which could lead to death or grave injury if it is not avoided. Caution: Indicates a low-risk hazard which could lead to minor or moderate injury if it is not avoided. Notice: Indication of possible property damage without injuries.
  • Page 9: Obligations Of Personnel

    aircleaner • The safety awareness of the personnel must be tested regu- larly. The installation and operating instructions must be stored in a suitable, dust-proof and damp-proof place. The place of storage must be easy to access and clearly visible at all times for every person using the system.
  • Page 10: Safety Instructions Relating To Fire Hazards

    • aircleaner Safety instruc- The sasoo is only intended for the extraction of air contam- tions relating to inated with aerosols in non-flammable concentrations. The fire hazards filter unit is designed for the precipitation of non-explosive aerosols, dusts and gases. The extraction of potentially explosive mixtures is prohibited..
  • Page 11: Safety Instructions For Crm Substances

    aircleaner • Note that the filter materials are also flammable, and may emit toxic gases and vapors if ignited. Safety instruc- Extraction and filtration of carcinogenic, mutagenic or repro- tions for CRM toxic substances (CMR substances ) is not permitted. substances Safety at work Before installing and starting up the unit, read the operating...
  • Page 12 Always comply with the applicable regulations for waste disposal when disposing of clogged filter media. • Only use genuine spare parts and wearing parts from ULT AG. • Improper work on the machine can compromise safety. • Do not use a liquid spray lance to clean the sasoo.
  • Page 13: Residual Risks

    aircleaner • Residual risks Guarding against Access to all moving parts (fan, motor) is protected by fixed mechanical guards which are securely fastened and require the use of hazards tools for removal. RESIDUAL RISK: • Injuries may result if tools are used to remove a securely attached permanent guard while the unit is running.
  • Page 14 • aircleaner Guarding against At the end of their service life, the sasoo, the filter inserts, and hazards during other accessory parts must be disposed of in accordance with disposal the applicable rules and regulations. RESIDUAL RISK: • If disposal is not performed correctly there may be a health risk and a risk of polluting the environment.
  • Page 15: Unit Components And Technical Data

    aircleaner • Unit components and technical data Rating plate The rating plate is an integral part of the unit and must never be removed or altered! The specifi cation of the type is unit-dependent. sasoo aircleaner 230 V 50Hz 4 A Unit components and technical data...
  • Page 16: Technical Overview

    • aircleaner Technical overview Intake grille Screw connection filter chamber Unit door Exhaust grille Filter reset button Stand with swivel joint Boost button for temporary amplification LED light for status indication of the extraction power Potentiometer for setting the On/Off switch extraction power Mains connection Unit components and technical data...
  • Page 17: Technical Depiction

    aircleaner • Technical depiction Unit components and technical data...
  • Page 18: Technical Data

    • aircleaner Technical data Technische Daten Dimensions Performance data Width 600 mm Volume fl ow max. 750 m³/h Height with stand 1,750 mm Max. volume fl ow 1,400 m³/h (with mounted (boost mode) castors +53 mm) Depth with stand 600 mm Negative pressure max.
  • Page 19 aircleaner • Technical data Noise level Average value at 1 m distance all around the unit 52 dB(A) Material (housing) • Powder coated aluminum sheet • Chemical resistant • Corrosion resistant • Temperature resistant Equipment • Continuously adjustable air flow control •...
  • Page 20: Connections And Control Elements

    • aircleaner Connections and control elements Electrical interfaces Connection for the power cord Mains voltage fuse (4 A) Electrical Connect the sasoo to the 230 V / 50 Hz power supply using connection the mains cable and plug provided. The power supply line must be fuse-protected with at least 5 A.
  • Page 21: Function And Type Of Operation

    aircleaner • Function and type of operation Functional principal The blower installed in the sasoo generates a vacuum at the intake grille on the top of the unit. Airborne substances can thus be sucked in directly from the room air. The air sucked in with pollutants flows through the HEPA filter in the sasoo.
  • Page 22: Filter System

    • aircleaner The sasoo is an important element of health protection and has been proven to reduce aerosol exposure for rooms up to 100 m², and thus the risk of infection. A 6-fold air exchange is recommended. (Source: Deutsches Beratungszentrum für Hygiene (German Advisory Center for Hygiene): SARS-CoV-2 (COVID 19);...
  • Page 23: Transport And Storage

    aircleaner • Transport Comply with the following conditions for transport and and storage storage: • Temperatuer: 5°C to +55°C • for a short time (max. 24 hours): up to +70 °C • Relative humidity: 0 - 65 % relative humidity (non-condens- ing) The stability of the unit is at risk when transported with indus- trial trucks.
  • Page 24 • aircleaner Set up without castors Place the unit stand at the installa- tion site. Carefully place the unit on the unit stand and lower it. Screw the grub screw into the nut using an Allen key to secure it. The unit can rotate so it can be orientated to meet the respec- tive requirements.
  • Page 25 aircleaner • Set up with castors Place the unit stand on its side. Mount the unit castors according to the illustration. (Allen key) Notice: Mount castors with brake side by side. Place the unit stand at the instal- lation site. Apply the brakes to the castors.
  • Page 26 • aircleaner Attach warning tape to the unit base on two opposite sides (optional).. To brake the castors, press the brake lever down. To release the brake, pull the brake lever upwards. Danger! Moving the unit by means of the mobile stand (with castors) is only permitted on even surfaces.
  • Page 27: Start-Up

    aircleaner • Start-up Unpack and set up the sasoo. • Open the three latches on the left side of the unit using a tool and open the unit door. • Install the fi lter according to the fi lter replacement instructions.
  • Page 28: Operation

    • aircleaner Operation Start the sasoo by switching the On/Off switch . Before commissioning, check that the air inlets and the air outlets of the unit are free and not covered. The indicator light signals the status of the unit, the HEPA fi lter and the CO content of the room air.
  • Page 29: Shutdown

    aircleaner • In boost mode, the unit’s volume increases to 68 dB(A). Indicator light The indicator light on the front of the unit reports the current status of the filter and the CO content in the room. Display Status Constant green Normal operation Flashing red Filter replacement necessary after 1,500...
  • Page 30: Maintenance And Servicing

    ULT Service by arrangement with ULT AG. Further actions in addition to the points listed above can be performed by ULT Service by arrangement with ULT AG. For your own safety, wear your protective equipment, i.e. at least a breathing mask (filter category P3) and gloves during...
  • Page 31: Filter Replacement

    aircleaner • Clean the area where the work was performed after any maintenance work. Perform maintenance work only when the equipment is disconnected from the power supply and voltage-free. Comply with the following points: • Switch off the unit and secure it against switching on again. •...
  • Page 32: Change Hepa Filter

    • aircleaner The storage filter elements are not suitable for cleaning with compressed air. Blowing out the filter destroys the filter dia- phragm and accumulated dusts are released. If the indicator light on the front of the unit flashes red, it is necessary to change the HEPA filter.
  • Page 33 aircleaner • Carefully remove the saturated filters and place them in a suitable disposal container that can be closed with an airtight seal. Maintenance and servicing...
  • Page 34: Change Activated Carbon Filter

    • aircleaner Carefully insert the new HEPA filter. Insert the filter rails, close the knurled screws by turning them clockwise. Close the door and screw the side latches onto the door using an Allen key. Reset the filter status. To do this, press the reset button for 7 seconds.
  • Page 35 aircleaner • Fit the new filter mat in the filter cartridge. Carefully insert the filter cartridge. Close the door and screw the side latches onto the door using an Allen key. Reconnect the power plug. Do not put any unit into operation that is damaged or incomplete! The owner of the waste, in this case usually the producer of the waste, is responsible for disposing (recycling or disposal)
  • Page 36: Possible Malfunctions

    • aircleaner Possible cause Remedy Possible malfunctions Fan does not start No power supply to the unit Check the power supply at the socket outlet Error in the unit/ Repair by specialist (specialist control electronics dealers) Unit fuse defective Replace fuse Insufficient extraction and filtration power Obstruction of the Check the intake and exhaust air...
  • Page 37: Replacement Filter

    Activated carbon filter inserts 4-00737 Always state the article number when placing your order. Use only genuine spare filters from ULT AG to ensure the safety and functional reliability of the unit. Any and all of the guarantees and warranties on the unit provided by us become null and void when spare filters from other manufacturers are used or applied.
  • Page 38: Service

    Notices on ULT AG products are designed exclusively for commercial electronic device use. ULT AG is registered as a manufacturer in Germany under disposal the WEEE reg.no DE 42863881 with the national register for waste electric equipment (Stiftung Elektro-Altgeräte EAR) in...
  • Page 39: Eu Declaration Of Conformity

    aircleaner • EU declaration of conformity...
  • Page 40: Confirmation Of The First Electronic Test According To Dguv

    • aircleaner Confirmation of the first electronic test...
  • Page 41 aircleaner •...
  • Page 42 • aircleaner...
  • Page 44 ULT AG Am Göpelteich 1 02708 Löbau, Germany Tel.: +49 35 85 / 41 28 0 Fax.: +49 35 85 / 41 28 11 info@sasoo-aircleaner.com • www.sasoo-aircleaner.com...