• aircleaner

Technical data

Technische
Daten
Dimensions
Width
Height with stand
Depth with stand
Weight with fi lter
Temperatures
Ambient air
during operation
Transport and
storage
Intake process air
Air
Humidity
Air intake
Air exhaust
18
600 mm
1,750 mm
(with mounted
castors +53 mm)
600 mm
90 kg
min. 10 °C,
max. 35 °C
max. 70 °C
min. 10 °C,
max. 60 °C
10 - 80 %
(non-condensing)
Intake grille, top
Outlet grille, bottom
Performance data
Volume fl ow max.
Max. volume fl ow
(boost mode)
Negative pressure max. 1,000 Pa
Room volume,
6-fold air exchange
Room volume,
6-fold air exchange
(boost mode)
Electrical connection
Rated voltage
Nominal frequency
Rated current
Rated power
consumption
Protection level
Unit components and technical data
750 m³/h
1,400 m³/h
up to 122 m³
(approx 50 m² with
2,3 m ceiling height)
up to 232 m³
(aprox. 100 m² with
2,3 m ceiling height)
1~230 V
50 Hz
4,0 A
0.75 kW
IP 54