- Always place the dispenser in its vertical position,
on a surface which can capably support its weight.
- During use this machine must remain in
its upright position.
- Adequate ventilation must be allowed for - we
recommend using the supplied ventilation ducting kit.
- Keep the machine away from sunlight, heat and moisture.
- The environment where this machine is installed must be
free of dust and corrosive/explosive gases.
Basic Troubleshooting
Problem/Report
No Water Dispensing
No Sparkling Water -
If applicable
Poor Quality Carbonation -
If applicable
Warm Drinks
Possible Cause
Water Pressure Regulator
No CO2 pressure, check by operating
pressure relief valve on carbonator tank.
Carbonator Tank Not Filling
Incorrect CO2 Pressure
Air in Carbonator Tank
Residue in Carbonator Tank
Carbonator Tank is Overfilled
Insufficient cooling air flow through the fridge.
Compressor not running.
Eliwell fridge controller not operating.
PCB not operating.
Fridge failure.
Suggested Action
Contact your distributor.
Check CO2 bottle, regulator and non- return
valve. Supply pressure should be 58 psi (4bar),
adjust or replace as necessary.
Contact your distributor.
Check CO2 bottle, regulator and non- return
valve. Supply pressure should be 58 psi (4bar),
adjust or replace as necessary.
Isolate the power supply and operate the spar-
kling water tap until gas is expelled. Allow gas
to expel for 5 seconds. Switch on power supply
and allow the tank to refill.
After prolonged use, a surface film can develop
within the carbonator tank. Refer to cleaning
and sanitising instructions.
If pump runs continuously, contact your
distributor.
Contact your distributor.