Nokia NPC-1 Series Troubleshooting Instructions page 29

Table of Contents

Advertisement

PAMS Technical Documentation
Power control loop
Basically, the power detection is done with the Power detector module and power con-
trol is done inside the SAFARI. Power detection is similar for both bands, except that
both bands have their own coupler.
Is PWRDET vs.
output power OK?
See chart below.
Y
Is DAC value vs.
PWRDET (mV) OK?
The detected voltages are illustrated in the following table and diagram:
Table 3: Typical detected voltages at power levels PL2...PL10
800A
Pout
PL
dBm
2
25.5
3
21.5
4
17.5
5
13.5
6
9.5
7
5.5
8
-
9
-
§0
-
Note: DAC values may vary about +- 20%
Note: TXPWRDET is the difference between TX on burst and off burst.
Issue 1 10/01
Figure 13: Fault tree: Power control loop
Check VR2 and
N
RFTEMP .
Check C930, C931
and PWRDET
module.
N
Check UEM
(BaseBand)
TXPWRDET
dac
mV
559
1475
388
1023
234
618
140
371
81
215
45
120
-
-
-
-
-
-
ãNokia Corporation
Troubleshooting Instructions
Note !
See PWRDET vs. Output
power curve
800D
Pout
TXPWRDET
dBm
dac
27.3
671
23.3
465
19.3
281
15.3
168
11.3
98
7.3
54
3.3
31
-0.7
15
-4.7
5
NPC-1
Mv
1771
1228
742
445
258
144
82
40
14
Page 29