8.

RS232 CONTROL TOOL

RS232 port configu ation tool is one control tool running on PC to pro-load the RS232
commands for this device to control the display. Connect a PC to the de vice via a UART-to-USB
cable, running the Uart port configu ation tool to set the connection par a meters correctly
before send the pro-loading commands to the de v ice. The baud rate for the device is 57600.
Uart port configu ation pool menus are described below:
• Baud rate: Choose the correct baud rate according to the sink de vice, then click "Connect" to
connect with the de vice.
Note: This might be different from the setting of 57600 abo v e and is determined by the sink
device you are connecting to.
• Power on: Pre-load and store the command for "power on " to a sink de vice, then click "Send"
to send and store it on the de vice.
• Power off: Pre-load and store the command for "power off " to a sink de vice, then click
"Send" to send and store it on the de v ice.
Note: If the sink device requires hex commands, make sure the Hex box is checked.
• Delay: Set delay time (0~30minutes) the sink device will power off automatically after it
cannot detect the input signal, then click "set" to tak e effect.
• Set Terminator: Select the command ending after each RS232 command that y o u are
sending from this device to the sink de vice. Then click "Set" to tak e effect.
• Set Relay Mode: Set relay mode for the sink de vice.
Latch – relay closes and latches when it is triggered;
Momentary – only closes for a moment and then opens after it is triggered.
Then click "Set" to tak e effect.
• EDID Write: Import EDID file to this d vice.
Choose File – click to browse for the EDID file on our computer.
Import – click to import the EDID file into this dvice.
Note: After the new EDID file is imported to this dvice, please set the EDID switch to
position "9" and reboot this de vice, then the input EDID of this de vice will be set to the new
EDID instead of 1024x768@60Hz 2CH.
• API: Enter the API command in the " C ommand" textbox and then click "Send" to send
command to this device.
See below picture: