Symptom
Display is dead
!! LOW BATT !!
warning on display
Display flashes and dial
pointer resets or
vibrates
Display gives a fixed
temperature reading
Display gives a fixed
reading of 0 ° C or 0 ° F
when temperature is
above 70 ° C or 160 ° F
All sensors show fixed
high values
Peak values not updated Gate value set too
38
Possible Cause
Power switch is off
Turn on
Battery is dead
Recharge or replace
battery
Power connection
Check if battery is
is faulty
connected correctly. Check
power lead continuity
Battery is almost
Recharge or replace
dead
battery
Power connection
Check power lead
is faulty
continuity
Battery is almost
Recharge or replace
dead
battery
Power connection
Check power lead
is faulty
continuity
Temperature
Replace sensor
sensor has failed
Faulty sensor
Check continuity of sensor
connections
leads
A temperature
Replace sensor
sensor has failed
Faulty sensor
Check continuity of sensor
connections
leads for open circuits.
Switch 1 (Peaks)
Return unit for repair
faulty
Change Gate RPM in the
high
display configuration menu
Internal memory
Return unit to Stack for new
battery dead
battery service
STACK Dash-2 Kart Logger