3.1 Connecting the terminal to the electric mains ........21 3.2 Connecting the terminal to the weighing platform ........ 23 3.2.1 Analogue cells connections ............... 23 3.3 D70ES serial output connection ............24 3.3.1 COM1 Serial port connection ..............24 3.3.2 COM2 Serial port connection ..............25 4.
Page 4
D70ES 4.2 Description of the keys ................ 30 4.3 On-off key of the terminal ..............32 4.3.1 Auto shutdown ..................33 5. USING THE TERMINAL ................34 5.1 General information ................34 5.2 Weight reset ..................35 5.3 Entering tare for acquisition ..............35 5.4 Tare display ..................
Page 6
D70ES 9.4.6 Net weight request..................65 9.4.7 Tare transmission request ................. 65 9.4.8 Scale status transmission request ............. 65 9.4.9 Scale status transmission request ............. 65 9.4.10 Scale reset ....................67 9.4.11 Tare acquisition ..................67 9.4.12 Entering a tare ..................67 9.4.13 Deleting an entered tare .................
Page 7
D70ES 10.4.2 Weighing operation request from serial command with transmission at end of operation ....................76 10.4.3 Weighing request from key and transmission from serial command ..76 10.4.4 Weighing and transmission request from serial command ...... 77 10.4.5 MP and MC remote commands with checksum ........77 10.5 MPP response format ...............
D70ES GENERAL INFORMATION 1.1 Declaration of conformity See QUICK START manual. 1.2 Introduction ✔ The purpose of this manual is to instruct the operator on the prescriptions and essential criteria for the installation, safe use and methodical maintenance of the weighing system, using texts and figures to support the explanations.
Page 10
D70ES ✔ All the technical information contained in this manual is the exclusive property of the Manufacturer and must be considered reserved. ✔ The reproduction and disclosure, even partial, of this manual on paper, digital support or on the WEB without written consent from the Manufacturer is prohibited.
D70ES 1.3 Symbols The following symbols are used in the manual to call the reader's attention to the different danger levels in the "Use and maintenance" of the instrument. DANGER Information or procedure which, if not carried out exactly, can cause death or severe personal harm.
The D70ES model of the digital weight indicator performs extremely accurate and reliable weighing operations. The field of use of the D70ES version referis, above all, to the industrial and commercial weighing sector thanks to its configuration that allows its easy insertion on the weighing platforms.
Page 13
D70ES AVAILABLE OPTIONS: ✔ Analogue output 16 bit resolution, 0-10 VDC, 0-20mA, 4-20 mA ✔ TCP/IP Ethernet port (10/100Mbps) ✔ 4 inputs / 4 outputs optoisolated 24 VDC 200mA ✔ MPP Alibi Memory (Software enabling) The options can be installed simultaneously.
D70ES 1.5 Technical features of the terminal Power supply 110-240 VAC 50/60 Hz internal 12 VDC/3 A(Min. 11 V - Max. 15 V) Direct Maximum absorbed power 15 W up to 12 350Ω analogue cells or Connectable cells to 24 700Ω analogue cells Minimum load cells impedance 29Ω...
D70ES 1.7 Instructions for the disposal of waste electric and electronic equipment This symbol on the purchased weighing instrument indicates that: ✔ this electric or electronic appliance cannot be disposed of as municipal solid waste; ✔ it must be disposed of separately;...
D70ES 1.8 Instructions for requesting technical assistance In the event of an operating fault or failure requiring the intervention of specialist technicians, contact your nearest assistant centre or contact the manufacturer directly. To speed up problem solving, communicate the serial number of the instrument found on the stamped plate.
D70ES 2. SAFETY PRESCRIPTIONS 2.1 Prohibited use The purchased instrument is a weighing system and has been designed and manufactured as such. It is intended primarily for weighing goods. ✔ It is prohibited to use the terminal without taking the necessary precautions for its safe operation.
Page 19
D70ES ✔ If the terminal needs to be connected to other devices such as computers, disconnect them from the mains before making the connections. ✔ Maintenance and/or repairs must only be carried out by authorised personnel. ✔ Always unplug the terminal and wait a few minutes before accessing its internal parts.
D70ES 3. DELIVERY AND INSTALLATION Figure 3.1 - Back of the D70ES terminal 1. 12 VDC, 3Amp direct power supply input terminal block 2. 90-240 Vac 50/60 Hz Power supply input 3. Connection terminal block to the weighing platform 4. Connection terminal block to the serial ports...
D70ES 3.1 Connecting the terminal to the electric mains DANGER The power cable plug has IP20 protection rating. Therefore, set-up a connection to the electric mains that is suitably protected according to the environmental conditions. DANGER Check that: ✔ the voltage and frequency of the terminal's electric power line are as indicated on the stamped plate at the bottom of the terminal;...
Page 22
D70ES Also provide a disconnecting switch upstream of the power line. The disconnecting switch must be accessible when performing maintenance on the system. Essential features of the power cable: ✔ double insulation cable with 3 coloured internal conductors (line=brown, neutral=blue, earth=yellow-green) ✔...
D70ES 3.2 Connecting the terminal to the weighing platform 3.2.1 Analogue cells connections The following diagram shows the pin number of the analogical scale input connector used for connection to the load cell. Phoenix MKDS 7 p 3.81 SIG -...
D70ES 3.3 D70ES serial output connection The indicator has two serial ports, one RS232, the other can be configured as RS232, RS422 or RS485. 3.3.1 COM1 Serial port connection Phoenix MKDS 4 p3,81 RS232 TX Data transmission RS232 RX Data reception...
D70ES 3.3.2 COM2 Serial port connection Phoenix MKDS 10 p. 3,81 +12 VDC RS422 TX+ (J10 1-2) Data transmission + RS422 TX- (J12 1-2) Data transmission - RS422 RX+ (J14 1-2) Data reception + RS422 RX- (J15 1-2) Data reception -...
Page 26
D70ES JUMPER SETTINGS PRINTED CIRCUIT BOARD REVISION "A" Jumpers for use of RS485 /RS422. J18 1 J18 2 Inserted (Closed) RS485, Open RS422 J19 2 J19 2 J18 - J19 ATTENTION 1-26...
Page 27
D70ES ATTENTION Maximum operating conditions foreseen by standard RS422: Maximum transmission distance = 1200 m Maximum voltage at ends = ± 7 Vdc For connection to external devices, use a shielded cable by connecting the shield to the signal of the relative connector...
D70ES 4. COMMANDS, INDICATIONS, SWITCHING ON AND OFF 4.1 Display of weight and accessory signals Terminal display Weighing symbols Keyboard Figure 4.1 - Front of the terminal The indications relating to the operations performed by the indicator are presented in the most extended form possible, while universally adopted symbols are used for the weighing data.
Page 29
D70ES The following is a list of the weighing symbols with their meanings: "Center zero" symbol Indicates that the weight detected by the platform is close to zero, ranging within -1/4 + 1/4 of the division. Stable weight signal Indicates that the displayed weight is stable and can be printed and/or transmitted.
D70ES 4.2 Description of the keys Refer to Figure 4.1 reference 1: Switching from gross weight mode to net weight mode Entering the ID value of the data recall (RCD) If enabled, it switches between primary and secondary unit of...
Page 31
D70ES Tare display key Pressing this key displays the set tare. Print and/or transmission start key Press this key allows printing the weighing data and/or serial transmission of a data string on the configured port. On-off key Pressing this key switches the terminal off or on.
D70ES 4.3 On-off key of the terminal DANGER Before switching on the terminal, check: ✔ that the electric frequency and voltage match those required by the terminal; ✔ the presence and integrity of the protective casings; ✔ the presence of warning and danger plates.
D70ES WARNING The on-off key can be disabled during installation. In this case, the customer must set up an accessible disconnecting switch. This feature is used if the terminal is installed in places that are not easily accessible (e.g. at a height of 3 m). In this case, the terminal is always on and to turn it off you must the disconnecting switch.
D70ES 5. USING THE TERMINAL General information The keys described in par. 4.2 are used to browse the menus, sub-menus and parameters. In particular is used to: ✔ enter the additional data, submenus and parameters; ✔ store the value of the displayed parameter;...
D70ES 5.2 Weight reset With the platform empty, if the display shows a value other than zero, press to reset. Resetting only takes place if the conditions specified in par. 4.2 are verified. 5.3 Entering tare for acquisition Place the weight to be acquired as tare value on the platform, and press .
D70ES 5.6 Tare deletion To delete a tare entered on the terminal and restore the read out of the gross weight, press 5.7 Gross/Net mode change When a tare is in use, you can change Gross/Net display mode by pressing ;...
Page 37
Date - time – code -- weighing number – tare total – net total and piece total (if Piece func.) In case of double weighing operation the tare values are omitted. After printing a total, D70ES displays the message “Azzert”, pressing resets the total, pressing 1-37...
Page 38
D70ES or letting the display time expire (about 3 sec) does not. Attention the general total reset also resets all the other totals. NB: the terminal is able to store 8000 weighing and resetting operations; when this limit is reached, the NO TOT message is displayed...
Page 39
D70ES Automatic shutdown NO not activated YES activated Shows the terminal power supply voltage, useful in VBAT case of battery power supply. Displays the weight in high resolution for a few H.R.WEIGHT seconds. The weight can also be displayed in the case of a scale in underload.
D70ES 5.11 CPE mode operation When configured in piece count operation (the selection can be made from SETUP or by user by pressing ), the terminal can feature the following functions: ✔ display the number of pieces, average unit weight (from here on AUW) and weight;...
D70ES ✔ pressing displays the calculated average unit weight. If the set unit of measurement is kg and the AUW is less than 1 kg, the AUW value will be displayed in g. The AUW is always positive. ✔ if the weight does not stabilise and the message WAITING remains, you can exit the procedure by pressing .
D70ES 5.13 Double weighing operation mode (input weight output weight) This detects the weight of a transport vehicle at two different weighing ranges and calculates the delta between the two values. This system is generally used for ground weighing. This function requires a printer to be connected. A...
D70ES with the related code. ✔ Before performing the second weighing press , enter the code issued with the first weighing using the numeric keypad and press the print key ✔ The terminal loads the first weight and calculates the value provided by the difference with the second weighing, printing the result on the printout ✔...
D70ES 5.15 Operation in extraction mode This operation, once selected during installation (NOVRAM -> SETUP ->PARAMS->CONF->FUNZ-> PESO) and associated with the I / O devices, is used to perform simple extractions at one or two speeds. In SETUP it is necessary to set the I / O for : "START", "STOP", "ESTRAZ"...
D70ES 5.16 Operation in FILL/EMPTY This special function allows the terminal to be used in extraction mode with particular operating characteristics. To activate this function, select parameter FIL.EMP in NOVRAM -> SETUP - >PARAMS->CONF->FUNZ-> FIL.EMP. The FILL and EMPTY items appear in the main menu and should be selected for loading and unloading operations, respectively.
Page 46
D70ES EMPTY unloading procedure . ‘EMPITY’ will appear on the display. 1) Press 2) When "EMPITY" appears, press to display the last weight value set for this procedure. 3) Press again to accept the displayed weight value and enter the extraction procedure.
D70ES 6. OPTIONS 6.1 Operation with 12VDC, 3 Amp external voltage / 12Volt DC External Battery As an alternative to using the 90-240Vac internal feeder, the weight indicator can be powered with an external 12 volt DC / 3Amp. WARNING...
D70ES 6.3 Optional 4 input 4 output board Insert the board on pin strip 2x6 J25. OUTPUT OptoMOS voltage-free contacts Vmax 24 Vac/Vdc Imax 190mA . They have separate common connections. INPUT Galvanic insulation input Vmax 24Vdc. They require a dry contact closing the voltage generated inside the Input.
Page 50
D70ES Pin number IN/OUT Connector TYPE OF CONNECTION On clamp IN01 IN02 IN03 IN04 RESERVED COM_INPUT OUT01 COM01 OUT02 COM02 OUT03 COM03 OUT04 COM04 1-50...
D70ES 6.4 Optional 0-10V, 0-20mA, 4-20Ma analogue output board Insert the board on pin strip 2x10 J26 Alternatively, an analogue output is available on the connector in formats 0-10 V and 4-20 mA galvanically separated. The connection diagram is displayed in the table below.
D70ES 7. ERROR MESSAGES Problem Cause Solution OverLD Reduce the weight to a value below the maximum capacity The scale is in overload so as to bring it back to the weighing range. Undrld Reposition the scale plate. The scale is in underload Procedures that reset the weight.
D70ES 8. ERROR MESSAGES CODINGS Only one code is displayed with errors; to delete it, turn the terminal off and back on again. Problem Cause Solution Turn off the terminal and check whether the Scale connector is fitted on connector correctly.
D70ES 9. COMMUNICATION PROGRAMMING ON SERIAL LINES 9.1 Symbols The symbols employed to describe the characters on serial line are provided below. ✔ Normal characters are represented simply with their symbol. ✔ Command characters are in brackets and expressed in capital letters.
The following strings are available on COM1: EXTENDED, CB, PRINT,CMA, ESTNUM, STRCPE. The following strings are available on Ethernet (if optional expansion applicable): EXTENDED, CB, ESTNUM and STRCPE. 9.2.1 CB string (or Bilanciai) The transmitted weight is net. first start character of the string 1st character $(24H)
D70ES 9.2.2 Extended String 1st character first character of the string $(24H) net weight with sign and any 2nd-10th character decimal separator 11th character space <SP>(20H) tare with sign and any 12th-20th character decimal separation 21st character <SP>(20H) space 22nd-23rd <um>...
Page 57
D70ES When a bit has a value of "1" this means that the corresponding signal is in the true condition; the meaning of the signals is as follows bit 0 minimum weighing operation signal bit 1 blocked tare signal <s1>...
D70ES 9.2.3 Print string The remote controls and cyclical transmissions are disabled in this mode. This string must be selected if you need to connect a printer or have a string to transmit to PC, with the following features. To connect a printer: after selecting the “PRINT” string, set the type of printer (STB80, NEUTRAL, Q3 etc..) and its features (characters per row, cut, etc.)
D70ES 9.2.5 CPE String (STRCPE) first character of the string $(24H) 1st character net weight with sign and any decimal 2nd-10th character separator 11th character <SP>(20H) space tare with sign and any decimal 12th-20th character separation 21st character <SP>(20H) space 22nd-23rd <um>...
Page 60
D70ES Characters such as <s1>, <s2>, <s3>, <s4> are ASCII characters that must be interpreted as hexadecimals. Each character represents 4 bits with different meanings, for example incoming ASCII character "A" must be interpreted as hexadecimal digit "A"; bit3 bit2 bit1 When a bit has a value of "1"...
D70ES 9.2.6 ESTNUM String On request with address By selecting this option cyclical string transmission is disabled. Remote commands are used followed by the terminal identification number that must be entered in setup: “CONF”/ “NBIL”. See par. 9.4.23 “Remote commands with addressing”...
D70ES 9.3.2 Cyclical protocol The selected string (see par. 9.2 on page 1-62) is sent cyclically at a speed of 3 times per second. 9.3.3 On request protocol The selected string is transmitted by pressing Or by waiting for remote commands from an external processor.
D70ES 9.4 Remote command protocols Various commands are available on the serial line that make it possible to perform numerous operations from a remote device (PC, PLC, etc.). WARNING The remote commands are only active if the value EXTENDED is set for the TYPE parameter during instrument configuration.
D70ES 9.4.1 Response to incorrect command ??<CR><LF> This response string is sent: ✔ if the command syntax is not correct; ✔ if the command cannot be carried out. 9.4.2 Response to correct command If the command is accepted, and if it involves the transmission of information, the response will be represented by sending the requested data;...
D70ES 9.4.5 Gross weight request XB<CR> The terminal responds with the following string: n<SP><um><SP>B<CR><LF> 9.4.6 Net weight request XN<CR> The terminal responds with the following string: n<SP><um><SP>NT<CR><LF> 9.4.7 Tare transmission request XT<CR> The terminal responds with the following string: n<SP><um><SP>TE<CR><LF>...
Page 66
D70ES Characters s1 and s2 are ASCII characters that must be interpreted as expressed in hexadecimals. The bits identify the status of the weighing platform. <s1> bit 0 valid weight bit 1 stable weight bit 2 center of zero bit 3 net displayed <s2>...
D70ES 9.4.10 Scale reset AZ<CR> 9.4.11 Tare acquisition AT<CR> 9.4.12 Entering a tare nAT<CR> The AT command must be preceded by a weight expressed with a maximum of 7 characters, including the decimal separator. 9.4.13 Deleting an entered tare CT<CR>...
D70ES 9.4.14 General data table transmission request ND<CR> By sending this command the terminal responds with a sequence of strings ending with <CR><LF> each containing the number of the data and its description; below a table of managed data is provided by way of...
D70ES 9.4.15 General data request indicated with “n” Xln<CR> Using this command it is possible to read the current value of any one of the general data (if you are in the relative mode). 9.4.16 "y" value setting request in the general data identified by "n"...
D70ES 9.4.19 Division value request Xe<CR> The terminal responds with the string: e= n<SP><um><CR><LF> 9.4.20 Maximum capacity value request XM<CR> The response string is: Max= n<SP><um><CR><LF> where n is a 9 character numerical field. 9.4.21 Internal conversion value request XC<CR>...
D70ES 9.5 Remote commands with checksum Management of remote commands with checksum can be enabled during the installation phase (par. 11.4.4). Checksum mode increases security when terminal and PC communicate with each other since the following precautions are implemented: each remote command transmitted to the terminal must contain two checksum characters in a dedicated position;...
D70ES 9.6 Remote commands with addressing If the RS485 communication interface has been selected, it is necessary to add the number of the instrument that will be queried to the remote commands described in par. 9.4. The system is comprised of a Master terminal (a PC, for example) and several Slave terminals (weighing terminals, for example).
D70ES 10. MPP The D70ES is equipped with MPP memory to store the weight of each individual weighing operation in a permanent metrological memory and transmit the value to an external peripheral device together with an identification code that is automatically assigned by the terminal.
D70ES 10.2 Operation The MPP operating mode is defined during installation. The operating modes are divided into two groups: 1) the user work from on the terminal, by pressing to store and transfer the weighing operation data; 2) the user work from the external terminal (e.g. PC) according to the specific software.
D70ES If the terminal is equipped with a printer, press to print: displayed weight, related identification code, date and time. The serial number or mpp terminal number may also feature in the print header depending on the type of response selected during installation.
D70ES 10.4.2 Weighing operation request from serial command with transmission at end of operation After loading the weight onto the weighing platform, send the storage command and data request through the calculator: MP<CR> With an affirmative response the terminal stores the weight and transmits a data string described in par.
D70ES 10.4.4 Weighing and transmission request from serial command After loading the weight onto the weighing platform, send the storage command through the calculator: MP<CR> When the weight validity conditions are reached, the terminal stores the data. The external processor then sends the data request command: MP<CR>...
D70ES 10.5.1 STD Format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th-10th character NO<SP>STAB weight not stable MPP identification NO<SP>VAL<SP> invalid weight code or indications on ERRMEM<SP> weight scale status: storage error Weight with mark and any 11th-18th character...
D70ES 10.5.2 NTERM Format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th-6th character MPP terminal number ( 3 DIGITS 7th-13th character NO<SP>STAB weight not stable MPP identification NO<SP>VAL<SP> invalid weight code or indications on ERRMEM<SP> weight scale status:...
D70ES 10.5.3 NMATR Format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th-11th character Serial number ( 8 DIGITS) NO<SP>STAB weight not 12th-18th character stable MPP identification NO<SP>VAL<SP> invalid code or indications on weight scale status: ERRMEM<SP> weight storage error...
D70ES 10.5.4 STD-DA format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th -13 th Date (10 characters) Date (dd/mm/yyyy) Space(20H) 15 th-22nd Hour (10 characters) Hour(hh:mm:ss) Space(20H) 24th-30th character NO<SP>STAB weight not stable MPP identification NO<SP>VAL<SP> invalid weight code or indications on ERRMEM<SP>...
D70ES 10.5.5 NTERM-DA format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th-6 Terminal N.(3 digits) Terminal N. Space(20H) 8th -17 th Date (10 characters) Date (gg/mm/yyyy) 18th Space(20H) 19 th-26th Hour (10 characters) Hour(oo:mm:ss) 27th Space(20H) 28th-34th character NO<SP>STAB weight not stable...
D70ES 10.5.6 NMA-DA format 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th-11th Serial Number(8 digits) Serial N. 12th -21st Date (10 characters) Date (dd/mm/yyyy) 22rd Space(20H) 23rd -30th Hour (10 characters) Hour(hh:mm:ss) 31st Space(20H) 32nd- 38th character NO<SP>STAB weight not stable MPP identification NO<SP>VAL<SP>...
D70ES 10.5.7 ABTA Parameter If the "ABTA" parameter is enabled, the tare value is also shown in the selected MPP string, which is appended to the weight value. Specifically: 1) 10 characters of tare (8 weight + 2 UM) if string: "STD", "NTERM" or "NMATR".
Page 85
D70ES checksum characters are "6" (36H) and "2" (32H). 33rd – 36 th character <CRC> CRC16(optional) STD–DA + ABTA=YES MPP String the transmitted data is: 1st character $(24H) 2nd character M(4DH) 3rd character P(50H) 4th -13 th Date (10 characters)
D70ES 11. CUSTOMISATION 11.1 Introduction WARNING customisation procedures strictly reserved specialised staff. Nonetheless, the user is allowed to change some of the terminal operating parameters. It is nevertheless advisable to take great care in changing these parameters to prevent faulty operation due to incorrect settings.
SETUP function by pressing the 2F key; the verification counters are displayed and password setting requested. WARNING Attention: pay attention to password use since access to d70ES terminal setup may be locked. The password is requested when entering and exiting setup in case of changes;...
D70ES 11.3 Description of menus and submenus In setup mode, the operations available are divided into menus which, in turn, can be divided into submenus containing similar parameters. NOVRAM CONF See 11.4.1 BILAN See 11.4.2 D.CAMP See 11.4.3 COM1 See 11.4.4 COM2 See 11.4.5...
D70ES 11.4 NOVRAM menu the following submenus are under the NOVRAM menu; CONF – BILAN (M) – D.CAMP (M)- COM1- COM2 – LPT1 – COM.ETH (*) – LAN (*) – MPP – IO – U.ANALO – Fn KEY - DEV-ID.
D70ES 11.4.1 CONF terminal customisation submenu This parameter defines the terminal/serial number (max 8 MAT.S/N digits) This parameter defines the instrument number for any NBIL queries with protocols with address. SCATYPE ANALOG, REPEAT COM1, COM2, ETHERNET PORT Type of port used if the terminal is a repeater.
Page 91
D70ES 12H, 24H TIM.FMT To select the time format The AUTO SHUTDOWN function is not active AUT.OFF The AUTO SHUTDOWN function is active HIGH The display is set at maximum bringtness The display is set at minimum bringtness ILLUM TEMPOR...
D70ES 11.4.2 BILAN submenu This submenu contains the parameters for the scale; the relative documentation is included in the installer manual. 11.4.3 D.CAMP submenu This submenu contains the parameters relating to scale sampling; the relative documentation is included in the installer manual.
D70ES 11.4.4 COM1 submenu This submenu contains the parameters relating to the COM1 serial ports. 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 BAUD This parameter defines the baud-rate, i.e. the transmission/reception speed at which the data exits or enters the COM1 serial ports.
Page 94
D70ES EXTENDED, see par. 9.2.2 CB, see par.9.2.1 PRINT, see par. 9.2.3 CMA, see par. 9.2.4 TYPE STRCPE, see par. 9.2.5 ESTNUM This parameter indicates the timing that the string selected with the previous parameter must be transmitted at. RICH...
D70ES ACKNAK This parameter is only significant with CB, EXTENDED and STRCPE string. The string is transmitted only when is pressed . After transmitting the string, the terminal waits for the ACK or NAK acceptance character for a max of 3 seconds...
Page 96
D70ES NO, EXTENDED, CB, PRINT, CMA, TYPE STRCPE, ESTNUM, See COM1 TEMP TIME.TX See COM1 M.CHECK See COM1 1-96...
D70ES 11.4.6 LPT1 submenu This submenu contains the parameters that define the type of printer connected to the instrument. NEUTRAL printing is sent to a Neutral device, ie no specific processing is performed. STB80 Continuous module table printer. It manages 80 mm wide modules.
D70ES No cut is made. (TM295 only) LF.INIZ This defines the initial row feeds for single weighing printouts or double weighing at input (TM295 only) LF.USC This defines the initial row feeds for double weighing prints at output (TM295 only) BLK.CAR...
Page 99
D70ES This parameter indicates the timing that the string selected with the previous parameter must be transmitted at. RICH This indicates that the string (CB, EXTENDED or STRCPE) is only transmitted when the print key is pressed. Also, if EXTENDED is selected, the remote commands are active for interrogation.
D70ES 11.4.8 LAN submenu This submenu contains the configuration parameters of the ethernet board. IP address MASK1 MASK2 subnet mask MASK3 MASK4 GWAY1 GWAY2 Gateway ip address GWAY3 GWAY4 DNS1 DNS2 DNS ip address DNS3 DNS4 DHCP DISAB,ENABLE Universal coordinate time (default +1)
D70ES 11.4.9 MPP submenu This submenu contains the configuration parameters of the MPP memory COM1, COM2, COM.ETH,NO COPC This selects the PC communication port The weighing operation is performed after pressing the key RICH COM.SER The weighing operation is performed after receiving the serial command.
Page 102
D70ES max 3 digits) MPP Standard MPPSTA MPP +Print LOCAL MPP enabled but without PC transmission ACK is not enabled. ABACK ACK is enabled, after transmitting the MPP string, the terminal waits for a maximum time of 3 seconds for the ACK acceptance character.
D70ES 11.4.10 IO submenu This submenu contains the configuration parameters of the input/output contacts. Management time of the input output lines See TIME COM1 This selects 01 input operation DISAB Input disabled RESET Scale reset TAREIN Tare acquisition TAREOU Tare cancellation...
Page 104
D70ES menu. RANGE Output1 is activated in the weight interval defined by the range. The 'MIN1' and 'MAX1' messages appear in the terminal's main menu, i.e. the maximum and minimum weights of the weight range, respectively. ESTRAZ Output1 is activated by the star t signal. When the defined weight is exceeded or the STOP input is activated, the output is deactivated.
Page 105
D70ES menu. FIN.EST If extraction is activated on output1, the end extraction function can be selected on output2. Output2 is activated once the weight selected in extraction has been exceeded and is deactivated by the STOP command. STMP.OK This activates the output for 1 second if a...
D70ES 11.4.11 U.ANALO Submenu This submenu contains the configuration parameters of the analogue output. VOLT, I0_20, I4_20 TYPE This selects output in voltage (0-10 V) or in current (0/20 mA or 4/20mA) GROSS, NET, REFWEI DATA selects outgoing data VMIN...
D70ES 11.4.13 DEV-ID submenu This submenu contains the terminal’s identification parameters. Internal Serial number. MAC1 MAC address (1 part) MAC2 MAC address (2 part) 1-107...
Page 108
D70ES SOCIETÀ COOPERATIVA BILANCIAI SOC. COOP. BILANCIAI CAMPOGALLIANO A.R.L. 41011 Campogalliano (MO) Via Ferrari, 16 tel. +39 (0)59 893 611 - fax +39 (0)59 527 079 home page: http://www.coopbilanciai.it E-mail:cb@coopbilanciai.it servizio post-vendita after sales service service après-vente Kundendienstservice servicio post-venta serviço pós-venda...