Download Print this page

Preventative Maintenance - Pure Water PW90 Field Manual

Hide thumbs Also See for PW90:

Advertisement

1. Remove the filter door, grab bottom and pull out, then inspect for leaks.
2. Drain the unit from the drain tube located under the hot tank switch in the back of the unit.
3. Remove the top cover and tank lid.
4. Spray 1 part hydrogen peroxide to 4 parts water solution into the cold tank, let stand for 5 minutes and wipe clean with a rag.
5. Replace the lid and flush the tank.
6. Filters should be replaced using this schedule:
• Sediment= 1 year
• Pre Carbon= 1 year
• RO Membrane= 2-3 years
• Boost= 1 year
• Post carbon= 2-3 years
• Lead and Cyst= 1 year
7. Please see flushing instructions
8. Wipe down the outside of the unit and sanitize the water dispense area.
9. Reset the filters that were changed during the PM in the programing of the machine.
PW90 Display:
1.
Enter the program mode
2.
Wave hand over the hot button until the cursor is resting on "Filter life time set "
3.
Wave hand over the dispense button to select "Filter lifetime set".
4.
In this mode, the hot button will act as scroll and the dispense button as select.
5.
The cursor will first rest on enable/disable for the pre- sediment filter.
6.
To reset the filter, wave hand over the hot button until "Reset?" is blinking
7.
Wave hand over the dispense button one time
8.
Usage will change to 0 when complete
9.
To select the next filter, wave hand over the hot button. Repeat above until all desired filters are adjusted

Preventative Maintenance

Advertisement

loading

This manual is also suitable for:

Pw90ct