Advertisement

Quick Links

Midi-Classic
Operator's Manual
3725 Touzalin Avenue • Lincoln, NE 68507 USA
Tel: 402.467.9300 • Toll Free in the USA: 800.875.5915 • Fax: 402.467.9393
www.purewaterinc.com

Advertisement

Table of Contents
loading

Summary of Contents for Pure Water Midi-classic

  • Page 1 ™ Midi-Classic Operator’s Manual 3725 Touzalin Avenue • Lincoln, NE 68507 USA Tel: 402.467.9300 • Toll Free in the USA: 800.875.5915 • Fax: 402.467.9393 www.purewaterinc.com...
  • Page 2: Table Of Contents

    Cleaning the Boiling Tank ................14 Changing the Post Filter ................. 15 Steam Sterilizing ....................16 Cleaning the Exterior ..................16 Troubleshooting ......................17 Electrical Schematic ....................21 Exploded View ......................22 Parts List ........................... 23 23 23 23 page 2 Midi-Classic Owners Manual...
  • Page 3: Important Safety Information

    IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: This distiller is designed to be used only with Pure Water, Inc. accessories and replacement components. ♦ The physiological effects of the operation of this distiller, beneficial or otherwise have not been investigated by U.L.
  • Page 4: Introduction

    Introduction Congratulations on purchasing the finest home water distillation system on the market. With proper care and attention, the Midi-Classic will give you many years of top performance and high-quality drinking water. Please read this manual thoroughly before installing and operating your Midi-Classic.
  • Page 5: Optional Accessories

    Optional Accessories The following are optional accessories or maintenance items for the Midi-Classic. They may be purchased from your Dealer or Distributor, or directly from Pure Water, Inc. ♦ Demand Pump Kit, complete with a 6” lead-free faucet and tubing. To supply water directly to a remote location.
  • Page 6: How Your Distiller Works

    If filling the boiling tank manually, only fill water to the bottom of the water level indicator peg. * The Midi-Classic can be set so the boiling tank can be filled manually. There is an Operation Switch located on the side of the switch tray, accessed through the electrical side panel, see figure 1.
  • Page 7: Preparing For Installation

    ♦ The Midi-Classic can be installed on a countertop, table or on the floor. If the minimize scale Midi-Classic is installed on the floor, it must be at least eighteen inches above build-up in the boiling tank and drain valve.
  • Page 8: Installation

    Installation CAUTION: : : : : The Midi-Classic weighs approximately 42 lbs. Please use caution when removing it from the carton to prevent injury. 1. Open the carton. 2. Carefully lift the distiller out of the box so it remains in the upright position.
  • Page 9 Turn the handle counterclockwise to open the valve. Turn on the household water supply and check the connections for leaks. Tighten where required. Midi-Classic Owners Manual page 9...
  • Page 10 Tighten firmly. See figure 9. m. Turn the handle counterclockwise to open the valve. Turn on the household water supply and check the connections for leaks. Tighten where required. page 10 Midi-Classic Owners Manual...
  • Page 11: Installing The Boiling Tank Drain Valve

    1. Locate the power cord in the parts kit bag. Install the female end of the power cord into the outlet on the back of the unit marked “Power Cord Plug”. See figure 11. Figure 12 Midi-Classic Owners Manual page 11...
  • Page 12: Start-Up

    To steam sterilize your Midi-Classic: Note: Remove the red caps on the condensing coil outlet and storage tank inlet.
  • Page 13: Connecting The Post Filter

    11. Remove the silicone tubing used for steam sterilization. Important Note: Keep this you steam sterilize the tubing for future use. Midi-Classic every four months or if the unit If you purchased a demand pump, install it now by following the instructions included has been serviced.
  • Page 14: Maintenance And Cleaning

    Turn the valve labeled “Boiling Tank Drain” on the back of the Midi-Classic and allow the residue to drain into a sink, drain or bucket. Close the valve and turn the Power Switch to ON and water will begin entering the boiling tank.
  • Page 15: Changing The Post Filter

    4. Reinstall the elbows onto each end of the new post filter. Insert fully and pull to test. 5. Install the new post filter onto the condensing coil and storage tank outlet tubes. Insert fully. Midi-Classic Owners Manual page 15...
  • Page 16: Steam Sterilizing

    Steam Sterilizing 1. Turn the Power Switch to OFF. 2. Drain the storage tank by opening the faucet on the front of the Midi-Classic. 3. Turn the Fan Switch to “Sterilize”. 4. Disconnect the post filter by releasing the grey collets.
  • Page 17: Troubleshooting

    If the float inside the boiling tank is not moving freely, install a new float repair kit, with bushing and o-ring. ♦ IMPORTANT: IMPORTANT: IMPORTANT: Only authorized Dealers and Distributors of Pure Water, Inc. may IMPORTANT: IMPORTANT: access the electrical panel to change FUNCTION switch from “Automatic” to “Manual” mode.
  • Page 18 ♦ If the float is not moving freely, you may need to install a new bushing and o-ring or float repair kit. ♦ If the float ball is full of water, replace the float ball. page 18 Midi-Classic Owners Manual...
  • Page 19 If overload pops out again, disconnect the power and check electrical wiring inside the unit for a shorted wire or component. ♦ If wiring and components appear ok, replace defective circuit breaker. ♦ Check the power cord for damage. Midi-Classic Owners Manual page 19...
  • Page 20 Check with a volt-ohm meter. ♦ If pump will not shut off, you could have air in the line; clogged pump valve; defective pressure switch; or defective pump. page 20 Midi-Classic Owners Manual...
  • Page 21: Electrical Schematic

    Electrical Schematic Midi-Classic Owners Manual `page 21...
  • Page 22: Exploded View

    Exploded View page 22 Midi-Classic Owners Manual...
  • Page 23: Parts List

    54A ..7092 ... 70103A ..Fan Motor 54B ..7136 ....7136 ... Female 2-pin Connector * parts kit ** not shown on exploded view # sold separately 55 ... 7010 ....7010 ... Fan Blade Midi-Classic Owners Manual page 23...
  • Page 24 Form #6598, ©1999, Pure Water, Inc.

Table of Contents