Cameo XNODE 4 User Manual page 11

4 port ethnet node
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
SET TO PRIMARY ART-NET IP
After navigating to the menu item Home > Menu > Network > Static Settings > Set to primary Art-Net IP, a dialog as shown on the right will
appear. Press [Cancel] to abort or press [OK] in order to apply the following settings:
... Static Settings > IP Address is set to the primary Art-Net IP address (2.X.Y.Z). The values X, Y and Z are computed from the device's MAC address.
... Static Settings > Netmask is set to 255.0.0.0.
SET TO SECONDARY ART-NET IP
As Set to Primary Art-Net IP, but sets network settings to the following values:
... Static Settings > IP Address is set to the secondary Art-Net IP address (10.X.Y.Z).
... Static Settings > Netmask is set to 255.0.0.0.
ART-NET SETTINGS
Node-wide Art-Net settings can be configured under Home > Menu > Art-Net.
ART-NET VERSION
This section applies to firmware version 1.01 and later.
The menu entry Home > Menu > Art-Net > Art-Net Version provides the following selection:
 Art-Net 4: Select Art-Net 4 to use the advantages of Art-Net 4. This is the recommended setting.
 Art-Net 3: Select Art-Net 3 for backward compatibility.
A bullet point is shown next to the currently active setting. Use the encoder wheel to select the desired setting and push [OK] to apply the setting.
When Art-Net 4 is selected, each output port has an independent port address in the range of 0 to 32767, which is composed of an Art-Net
net, sub-net and universe number. This allows for configuring the node to any combination of Art-Net universes. When Art-Net 3 is active,
all ports of the node share the same net and sub-net numbers. For more information on the addressing of the Art-Net ports, see section
Representations of Art-Net Port Addresses in the appendix.
NET
This setting is only available when the Art-Net version is set to Art-Net 3 or with firmware versions prior to version 1.01.
To adjust the Art-Net net of the node, navigate to Home > Menu > Art-Net > Net and adjust the number using the encoder wheel. Once the
desired number has been selected, push [OK] to apply the new setting or press [Cancel] to abort.
This part of the Art-Net address was introduced with Art-Net 3. In order to work with Art-Net I and Art-Net II controllers, Art-Net net needs to
be set to 0.
Note that changing this setting while independent Art-Net universes are enabled still affects all Art-Net port addresses. For more informati-
on, see Independent Universes below.
SUB-NET
This setting is only available when the Art-Net version is set to Art-Net 3 or with firmware versions prior to version 1.01.
The Art-Net sub-net is configured under Home > Menu > Art-Net > Sub-Net in the same way the Net is configured.
Note that changing this setting while independent Art-Net universes are enabled still affects all Art-Net port addresses. For more informati-
on, see Independent Universes below.