9.6 -PROCEDURE FOR REMOVING THE COLUMN WITH FIXED DRUMS fig. 16
1) Disconnect and open the door to access the drum column and the solenoids.
2) After having opened the door remove the righthand and lefthand steel grates. Unscrew the self-
tapping screws clamped on the side of the cabinet near the fluorescent lamp to remove the
lefthand grate. Unscrew the screws M6 that clamp the mounting brackets to remove the
righthand grate. Before carrying out this procedure set out some reference points in order to
remount it in the original position.
3) Using the bar unhook the pistons from the drums, if the solenoid column is equipped with,
otherwise unscrew the column and remove it from the drums. Also here it is advise to set out
some reference points to remount the column correctly.
4) Close the door, put the vending machine on the back and open again the door.
5) Remove the bottom plate, unscrew and remove the gearbox unit.
6) Unscrew the plate holding the bush and remove the whole (part.1-2-3 fig 16). Set out some
reference points around the plate in order to remount everything in the correct position.
7) Move the column to the bottom of the machine so that its shaft exits the plastic bushing (part. 7
fig. 16).
8) Take out horizontally the column from the cabinet and lay it upside down on a pallet.
9) Remove the key (part. 4 fig. 16), the plugs (part. 5 fig. 16) that clamp the dragging hubs (part. 6
fig. 16) and take out the drums.
fig. P