5.1 Preparing Cables

Figure 5-1 Solar inverter cable connection
Table 5-1 Cables
No. Cable
1
DC input
power cable
RS485
2
communication
s cable
3
AC output
power cable
4
PE cable

5.2 Connecting a PE Cable

Context
It is recommended that the PE cable of the solar inverter be connected to a nearby ground
point. Connect the PE points of all solar inverters in the same array to ensure equipotential
connections to PE cables. Low-voltage solar inverters need to be grounded in type C mode.
Issue 03 (2020-06-03)
Type
Common outdoor PV cable
in the industry
Two-core outdoor shielded
cable
Three-core (U, O, and W)
outdoor copper cable
Single-core outdoor copper
cable
Copyright © Huawei Technologies Co., Ltd.
Conductor
Cross-Sectional
Area Range
2
3.5–5.5 mm
2
0.25–1 mm
2
3.5–5.5 mm
2
3.5–5.5 mm
5 Electrical Connections
Outer
Source
Diameter
4.5–7.8 mm
Prepared by
the customer
Prepared by
4–11 mm
the customer
10–21 mm
Prepared by
the customer
N/A
Prepared by
the customer
30