Primus I35/50 Programming Manual page 9

Ironing machines with insertion width 1400/1600/2000/2500/3200 mm and ironing machines with front/rear delivery with folder or without folder withinsertion width 2000/2500/3200 mm
Table of Contents

Advertisement

DIAGNOSTIC MENU („DG")
Displaying the state of inputs and outputs of the control unit with possibility to change the state of individual
outputs. Input to diagnostic mode is executed by set-up the item „dG" in initialization to „On" (by means
of „+" and „-" ) and confirmation by pressing „START" button. Go to individual items in diagnostic mode by
means of buttons „+" and „-". Change of individual output state is possible to do by holding the button „START".
Input
identification
I1
I2
I3
I4
I5
I6
I7
I8
I9
10
11
12
13
14
A1
A2
Output
identification
O1
O2
O3
O4
O5
O6
O7
O8
O9
10
11,12,13
A0
8
Description
Frequency inverter
Manual crank
Foot pedal of clutch
Bimetal of ventilator
Switch of programming
Gas low pressure
Alarm of gas ignition
Finger protector guard
Detection of linen (OPL) / coinmeter 1 (coin)
Incremental roller sensor - testing is not possible
Position of pressure roller 1 (OPL - ironer with
front/rear delivery) / coin meter 2
Position of pressure roller 2 (OPL - ironer with
front/rear delivery)
Trough position
Was not used
Actual temperature of ironing roller
Actual speed of ironing roller
Description
Heating 1
Heating 2
Frequency inverter
Blocking of clutch pedal
Pressure roller
Ventilator
Reversation of roller direction
Permit of inverter action
Increased speed of inverter (for the first fold on linen)
Direction of cloths delivery
Was not used
Speed of roller
PROGRAMMING MANUAL
508913C
PUBLICATION DATE 25 AUG 2006.DOC