If you need to lay the device down while it is out of the antistatic bag, lay it on
the antistatic bag. Before picking it up again, touch the antistatic bag and the
metal frame of the system unit at the same time.
Rack Warnings
If you plan to rack mount the AS 15MT, follow the rack manufacturer's safety instructions.
Install the enclosure only in a rack that has been properly secured in an area with
suitable environmental conditions.
Have someone assist you during physical installation.
To properly ventilate the system, you must provide at least 7.6 cm of clearance at the
front and back of the system.
To reduce the risk of personal injury or damage to equipment, always ensure that the
rack is adequately stabilized prior to extending a component outside the rack. A rack
may become unstable if more than one component is extended. Extend only one at a
time.
Do not stand or step on any components in the rack.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the manufacturer.
Do not overload the AC power supply branch circuit that provides power to the rack.
Observe extension cable and power strip ratings. Ensure that the total ampere rating of
all equipment plugged into the extension cable or power strip does not exceed 80
percent of the ampere ratings limit for the extension cable or power strip.
6