Specifications - DALEMANS D-TEX3F+ Instruction Manual

Table of Contents

Advertisement

5.

SPECIFICATIONS

To guarantee safety and performance, any gas detection installation must be calibrated and maintained regularly
according to the manufacturer's guidelines.
Brand
Principle and gas
concerned
Detection performance
Supply
Box
Connection
Outputs
Conditions of use
Certifications
www.dalemans.com
CHARACTERISTICS
Design and manufacture
Measurement principle
Methane (CH4)
Propane (C3H8)
Butane (C4H10)
Response time (T90)
Accuracy
Mains
Power
Current
Secured
Material
W
D
Dimensions (H x
x
)
Weight
IP protection index
Reversibility
Standard fixing
Cable input
Screwed terminal
Type
Output signal
Temperature
Humidity
Licence
Danger zones
Standards
Cell unit certificate
Marking
DALEMANS S.A.
Catalytic
0 - 100 % LEL
0 - 100 % LEL
0 - 100 % LEL
< 30 s
± 2 % range < 50 % LEL
24V
0.45 W ± 0.05
18 mA ± 2
12V
Flame-retardant and UV-stable plastic (UL-94V0)
147 x 119 x 51 mm
285 g
IP 65
YES
4 screws
1 x M20
3 x 0.75 - 2.5 mm²
1 x 3F
3-wire analogue voltage
0 °C - +50 °C
10 - 90% RH (without condensation) 90 - 110KPa
(ex) II 3G Ex nA d IIC T2 Gc Tamp: 0°C - +50°C
Zone 2
EN 60079-0, EN 60079-1, EN 60079-15
FTZU 15 ATEX 00032 U
CE, RoHS
|
16