Download Print this page

Beko BEKOMAT 32U Vario Instructions For Installation And Operation Manual page 9

Replacement unit

Advertisement

Control unit with cord
packing
(previous version)
17
1
15
12
11
13
14
5
Pos : 29 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1
Service-Unit BEKOMAT® 32U Vario / 32U Vario F
Control unit without
cord packing
(current version)
Prior to placing a previous version of the control
unit with cord packing (17) in the lower part of the
cover, the sealing mat (11) must be removed from
the service unit.
Installation of the control unit on the service unit :
1. Check whether or not the service unit (5) goes with
the control unit (1) (model designation and color of
the arresting hook).
2. Check whether or not the sealing mat (11) or the
sensor tube plate (14) with contact springs (13) are
clean, dry, and free from impurities.
3. Introduce the sensor (12) into the sensor tube plate
(14).
4. Hang the hook (15) of the control unit (1) in the
sensor tube plate (14).
5. Press the control unit (1) against the service unit
(5) and snap into place.
Start-up subsequent to maintenance measures:
Always carry out prior to the start-up:
Leak test of the screwed connector
Check of the electrical connections
Check of the correct engagement of the control unit
Control and maintenance
9

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Bekomat 32u vario fSubm32uvSubm32uvf