Generator Usage - GENERGY ROBUSTA Series Instructions For Use Manual

Gasoline generator
Table of Contents

Advertisement

Available languages

Available languages

6 Generator usage:

Connect the grounding (grounding Rod) as indicated in the attached figure. Check
with an electrician in case of any doubts.
GROUNDING
WARNING: Never connect the 230 voltage output of the equipment to a
building or house (not even during a power outage). The return of the main
network would clash with the generator's voltage and cause serious damage to the
equipment or even a fire.
WARNING: Do not connect in parallel with other generators, both will be
damaged and will be a fire hazard.
NOTE: Do not connect an extension to the exhaust.
NOTE: If a cable extension is needed, make sure you use a good quality
rubber extension (as per IEC245 or equivalent standards) and appropriate section:
 60.6 yd cable length: use a 0.05 in
 109.4 yd cable length use a 0.09 in
NOTE: Devices that use an engine such as compressors, water pumps,
saws, radials, etc. require up to 3 times more power for startup. For example, a
500 W water pump would need a 1500 W generator for startup. Verify that charges
upon connection do not exceed the maximum power of the group according to this
indication.
GROUNDING SYMBOL
2
cable
2
cable
13