Infrared Communication Failure - Nokia RM-14 Baseband Troubleshooting And Manual Tuning

Table of Contents

Advertisement

Nokia Customer Care
Tuning

Infrared communication failure

18
Figure 10:Infrared communication failure
IrDA Failure
Yes
Measure
No
VBAT at
C350 = 3,7-
4,2V ?
Yes
Measure
No
VFLASH1 at
C351=2,78V
Yes
Measure VIO
No
at
C352=1,80V
C353=1,80V
Yes
Measure
No
activity TXD
on N350 pin3
?
Yes
Replace N350
COMPANY CONFIDENTIAL
Copyright © 2004 Nokia. All Rights Reserved.
Baseband Troubleshooting and Manual
Defect PWB
Replace
Defect PWB
D200
Replace
Defect PWB
D200
Replace
Defect PWB
D400
RM-14
ISSUE 1 11/04